7. Technical specifications
EV Charging Station NS | ||
|---|---|---|
Input voltage range (V AC) | 170 – 265 V AC @ 50 Hz | |
Rated charge current | 32 A / phase | |
Nominal power | 22 kW | |
Self-consumption | 15 mA @ 230 V | |
Configurable min. / max. current | 6 - 32 A | |
Connector type | IEC 62196 Type 2, motorised cable lock | |
Cable detection | Proximity pilot (PP), current limited to the cable rating | |
GENERAL | ||
Means to Disconnect | External fuse or circuit breaker, max 40 A, depending on available input power | |
Configurable price/kWh calculator | Default setting: € 0.13 (adjustable) | |
Control type | Web interface, GX device, VictronConnect (locally via Bluetooth), VictronConnect-Remote (from anywhere via VRM), NFC | |
Light Ring | 55 configurable light effects available | |
Energy metering | Integrated metering IC | |
Protection | Internal RCD | |
Operating temperature | -25 °C to +50 °C | |
Storage temperature | -40 °C to +80 °C | |
Humidity | 95 %, non-condensing | |
Data communication | MQTT and Modbus TCP over WiFi/Ethernet, Bluetooth | |
Wi-Fi standards | 802.11 b/g/n (2.4 GHz only) | |
V2G | Prepared for V2G | |
ENCLOSURE | ||
Enclosure colour | Light Blue (RAL 5012) Traffic Black (RAL 9017), Traffic White (RAL 9016) covers sold separately | |
Power terminals | 6-10 mm² / AWG 10-8 | |
Protection category | IP44 | |
Ventilation | not required | |
Weight | 3 kg | |
Dimensions (h x w x d) | 372 x 292 x 122 mm | |
STANDARDS | ||
Safety | IEC 61851-1, IEC 61851-22 Detection for Relay Contact welded Detection for missing protective conductor Detection for missing Ground Detection for shorted CP Intrusion detection (in selected regions) | |
7.1. Dimensions

7.2. Drilling template