Skip to main content

MultiPlus

LED indications

LED_off.png LED off

LED_blinking.png LED blinking

LED_on.png LED on

LEDs

Description

MP_500VA_-_LED_1.png

On / Off / Charger-only switch = On

The inverter is switched on and supplies power to the load.

MP_500VA_-_LED_2.png

On / Off / Charger-only switch = On

The inverter is switched on and supplies power to the load. Pre alarm: overload, or battery voltage low, or inverter temperature high.

MP_500VA_-_LED_3.png

On / Off / Charger-only switch = On

The inverter is switched off due to one of the following alarms: overload, battery voltage low, inverter temperature high, or DC ripple voltage too high.

MP_500VA_-_LED_4.png

On / Off / Charger-only switch = On

The AC input voltage is switched through, and the charger operates in float mode.

MP_500VA_-_LED_5.PNG

On / Off / Charger-only switch = On

The AC input is switched through and the charge current is zero. The inverter is switched on and, in case of PowerAssist, assists the AC input by supplying additional power to the load the General chapter.

MP_500VA_-_LED_6.PNG

On / Off / Charger-only switch = On

The AC input voltage is switched through. The inverter is switched on and supplies power to the load or excess power to the mains.

MP_500VA_-_LED_7.png

On / Off / Charger-only switch = Charger only

The AC input voltage is switched through, and the charger operates in bulk or absorption mode.

MP_500VA_-_LED_8.png

On / Off / Charger-only switch = Charger only

The AC input is switched through, and the charger operates in float or storage mode.

Note: The inverter/charger will shut down if four abnormal events occur within 30 seconds. It can be reset by switching to Off and then to On again.

For the latest and most up-to-date information about the blink codes, please refer to the Victron Toolkit app.

Scan the QR code or click on the below link to go to the Victron software downloads webpage.

https://www.victronenergy.com/support-and-downloads/software

QR_code_blinkies.png