Standard settings: ready for use
On delivery, the Multi is set to standard factory values. In general, these settings are suitable for single-unit operation.
Warning
Warning: The standard charging voltage might not be appropriate for your batteries. Consult the manufacturer's documentation or your battery supplier for guidance.
Setting | Default value |
---|---|
Inverter frequency | 60 Hz |
Input frequency range | 55 - 65 Hz |
Input voltage range | 94 - 143 VAC |
Inverter voltage | 120 VAC |
Stand-alone / parallel / 3-phase | stand-alone |
Search mode | off |
Ground relay | on |
Charger on/off | on |
Battery charge algorithm | four-stage adaptive withBatterySafe mode |
Charge current | 100 % of the maximum charge current |
Battery type | Victron Gel Deep Discharge (also suitable for Victron AGM Deep Discharge) |
Automatic equalisation charging | off |
Absorption voltage | 14.4V |
Absorption time | up to 8 hours (depending on bulk time) |
Float voltage | 13.8V |
Storage voltage | 13.2V (not adjustable) |
Repeated absorption time | 1 hour |
Absorption repeat interval | 7 days |
Bulk protection | off |
AC input current limit | 12A (= adjustable current limit for PowerControl andPowerAssist functions) |
UPS feature on | on |
Dynamic current limiter off | off |
Weak AC | off |
Boost factor | 2 |
Programmable relay | alarm function |