ve.can:changing_nmea2000_instances [2019-05-26 07:58] mvaderve.can:changing_nmea2000_instances [2020-04-10 00:02] – [1. Introduction] mvader
Line 8: Line 8:
  
 For the displays to show these values at the right place, they need to know which voltage belongs to what battery. For the displays to show these values at the right place, they need to know which voltage belongs to what battery.
 +
 +Before going ahead and change instances, please make sure to first study [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|the NMEA2000-out chapter in the GX manual]].
  
 === How can I change the instances? === === How can I change the instances? ===
Line 15: Line 17:
   - Use [[http://www.actisense.com/|Actisense]] software & hardware. Can change both the device- and data-instances    - Use [[http://www.actisense.com/|Actisense]] software & hardware. Can change both the device- and data-instances 
   - Use [[https://www.maretron.com/|Maretron]] software & hardware.   - Use [[https://www.maretron.com/|Maretron]] software & hardware.
-  - From the commandline of a [[venus-os:start|Venus-device]]. Note that this is a software developer trick. Not for any day use.+  - From the [[open_source:ccgx:commandline|commandline]] of a [[venus-os:start|GX device]]. Note that this is a software developer trick. Not for any day use.
  
-=== Device instance vs the data instances === +=== Device instancedata instances and other instances === 
-There are two types of instances: device instances and data instancesAnd depending on the make and model of the displays being used (Garmin, Maretron, Raymarine, etcetera), you need to change one of them or both.+There various types of instances. Please make sure to study [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|the NMEA2000-out chapter in the GX manual]] before continuing.
  
-Both the device instance and the data instance of a product can easily be changed with both Maretron N2Kview as well as and Actisense PC software.+In summary, and as per NMEA2000 specification, it should not be necessary to change a data instance such as the DC instance.
  