4. Communication and interfacing
4.1. GX Device
The Lynx Shunt VE.Can (M10) can be connected to a GX device via VE.Can. The GX device will show all measured parameters, operational state, battery SoC and alarms.
Ensure that the VE.Can & Lynx Ion BMS (250 kbit/s) profile is selected on the GX device in Settings → Connectivity. This is the default profile for VE.Can communication. Note that the BMS-Can port cannot be used for this connection.
4.2. NMEA 2000
Communication with an NMEA 2000 network can be established via the Lynx Shunt VE.Can (M10) VE.Can connection together with a VE.Can to NMEA2000 micro-C male cable.
Supported NMEA 2000 PGNs:
Product Information – PGN 126996
DC detailed Status – PGN 127506
DC/Battery Status – PGN 127508
Switch Bank Status - PGN 127501
Status 1: Contactor
Status 2: Alarm
Status 3: Battery voltage low
Status 4: Battery voltage high
Status 5: Programmable relay status
Class and function:
N2K device class: Electrical generation
N2K device function: Battery