ve.can:nmea-2000:start
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
ve.can:nmea-2000:start [2016-12-01 09:51] – [1.1 Multis, MultiPlusses and Quattros] mvader | ve.can:nmea-2000:start [2019-10-05 11:36] – [1.3 VE.Can products (Skylla-i, Skylla-IP44, Lynx Shunt, Lynx Ion+Shunt and more)] guy_stewart | ||
---|---|---|---|
Line 26: | Line 26: | ||
When the Multis/ | When the Multis/ | ||
- | * Hub-4 and ESS Assistant | + | * Incompatible with Hub-4 and ESS Assistant, for Energy Storage Systems |
- | * Listing the installed Assistants on the CCGX / VRM Portal | + | * Listing the VE.Bus |
- | * Alarm information per phase (generic alarm information still works) | + | * Alarm information per phase does not work (generic alarm information still works) |
- | * Forwarding charge-current information of MPPTs. Solution: always install a BMV, which is needed anyway in a Marine installation. | + | * Forwarding charge-current information of MPPTs to the VE.Bus system does not work. Solution: always install a BMV, which is needed anyway in a Marine installation. |
Setting On/ | Setting On/ | ||
==== 1.2 BMV Battery Monitors ==== | ==== 1.2 BMV Battery Monitors ==== | ||
- | Use the [[https:// | + | Use the [[https:// |
Combining this with a CCGX on the same network is possible. Connect the CCGX to the N2K network as well, use our [[https:// | Combining this with a CCGX on the same network is possible. Connect the CCGX to the N2K network as well, use our [[https:// | ||
Line 47: | Line 47: | ||
* Lynx Shunt Battery Monitors | * Lynx Shunt Battery Monitors | ||
* Lynx Ion + Shunt all models | * Lynx Ion + Shunt all models | ||
- | * BlueSolar | + | * SmartSolar |
{{ : | {{ : | ||
Line 87: | Line 87: | ||
=== Q2: Can MPPT Solar Chargers with a VE.Direct port also be connected? === | === Q2: Can MPPT Solar Chargers with a VE.Direct port also be connected? === | ||
- | No, they cannot be connected. Even though the [[https:// | + | No, they cannot be connected. Even though the [[https:// |
Note that there are many more generic frequently asked questions answered in the [[https:// | Note that there are many more generic frequently asked questions answered in the [[https:// | ||
Line 110: | Line 110: | ||
* Victron BMS data | * Victron BMS data | ||
* Victron Tank sender data as well as tank sender data from other manufacturers. See chapter 1.2.7 in the [[ccgx: | * Victron Tank sender data as well as tank sender data from other manufacturers. See chapter 1.2.7 in the [[ccgx: | ||
+ | |||
+ | === Q5: Can integration onto Raymarine displays also be done without Empirbus NXT? === | ||
+ | |||
+ | No. | ||
+ | |||
+ | === Q6: What about Maretron and other brand tanksensors on the Ccgx? === | ||
+ | |||
+ | See chapter 1.2.7 in the [[ccgx: | ||
+ | |||
===== DISQUS ===== | ===== DISQUS ===== | ||
~~DISQUS~~ | ~~DISQUS~~ |
ve.can/nmea-2000/start.txt · Last modified: 2022-03-16 12:19 by stefanie