Line 343: | Line 343: | ||
Victron Energy B.V. | Victron Energy B.V. | ||
</ | </ | ||
+ | |||
+ | Switching all devices on VE.Can off (careful, when having NMEA2000-out enabled, or having an Inverter RS, also AC will be switched off!): | ||
+ | < | ||
+ | vreg -c socketcan: | ||
+ | </ | ||
+ | |||
+ | switching a specific device off: | ||
+ | < | ||
+ | vreg -c socketcan: | ||
+ | </ | ||
+ | Note that in above example the VREG data field (un32) is padded with zeros; current firmware requires that, future fw won't any more. | ||
+ | |||
+ | Switch a specific device on: | ||
+ | < | ||
+ | vreg -c socketcan: | ||
+ | </ | ||
+ | |||
+ | Seeing which devices are off and which are on goes like this. Press ctrl-C to stop the command. | ||
+ | < | ||
+ | vreg -c socketcan: | ||
+ | </ | ||
+ | |||
===== 5. VE.Direct products ===== | ===== 5. VE.Direct products ===== | ||
Line 402: | Line 424: | ||
- SSH into CCGX (make a root password by following instructions [[ccgx: | - SSH into CCGX (make a root password by following instructions [[ccgx: | ||
- | | + | |
- | - < | + | - Enable Remote Console on LAN: < |
- | - < | + | - Create the password file. Empty file means no password: |
- Reboot CCGX via SSH: < | - Reboot CCGX via SSH: < | ||
- Now you should be able to access Remote Console feature from VRM | - Now you should be able to access Remote Console feature from VRM | ||
- If you want to set a password, go to Settings -> Remote Console -> Enable password check | - If you want to set a password, go to Settings -> Remote Console -> Enable password check | ||
- | ===== 8. Enabling VRM two-way communication (Remote VEConfigure aka vrmpubnub) ===== | ||
- | If you have a CCGX already installed, but VRM two-way communication is not enabled, follow these steps to enable it remotely: | ||
- | |||
- | - SSH into CCGX (make a root password by following instructions [[ccgx: | ||
- | - < | ||
- | - VE.Configure should now be able to connect to the CCGX | ||