open_source:ccgx:commandline
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
open_source:ccgx:commandline [2018-12-06 13:16] – guy_stewart | open_source:ccgx:commandline [2019-04-15 21:10] – [5. VE.Direct products] mvader | ||
---|---|---|---|
Line 284: | Line 284: | ||
Querying devices | Querying devices | ||
Update end send | Update end send | ||
+ | </ | ||
+ | |||
+ | ==== 4.4 vreg: changing settings from the command line ==== | ||
+ | |||
+ | < | ||
+ | # vreg --help | ||
+ | vreg - Victron registers | ||
+ | |||
+ | -b,--bin | ||
+ | | ||
+ | |||
+ | -g,--get | ||
+ | Get a register. | ||
+ | |||
+ | -n,--nad | ||
+ | The NAD of the target device. | ||
+ | |||
+ | -r,--run | ||
+ | Keep running. | ||
+ | |||
+ | -s,--set | ||
+ | Set a register. Data is set with e.g. un16:2800 un16:12 | ||
+ | |||
+ | COMMON OPTIONS: | ||
+ | |||
+ | -c, --canbus | ||
+ | | ||
+ | | ||
+ | -c ? will list the available gateways. | ||
+ | |||
+ | -d, --dump | ||
+ | Dump the contents of the CAN bus frames. Specifying multiple times increases verbosity. | ||
+ | |||
+ | -h, --help | ||
+ | Print this help. | ||
+ | |||
+ | --log-before < | ||
+ | When set to non zero < | ||
+ | not enabled themselves, are nevertheless shown before an | ||
+ | log which is enabled. For example an error message will be | ||
+ | | ||
+ | | ||
+ | be preceeded by info messages | ||
+ | |||
+ | --log-after < | ||
+ | Like -log-before, | ||
+ | after a warning or error occured. | ||
+ | |||
+ | --silent | ||
+ | Only listen, no messages or acks are sent | ||
+ | |||
+ | -v --verbose | ||
+ | | ||
+ | |||
+ | Victron Energy B.V. | ||
</ | </ | ||
===== 5. VE.Direct products ===== | ===== 5. VE.Direct products ===== | ||
- | List all services running: | + | ==== 5.1 See connected devices ==== |
- | | + | < |
+ | # svstat / | ||
+ | / | ||
+ | / | ||
+ | </ | ||
- | Look for the product that you want to update, and claim the serial port: | + | ==== 5.2 Firmware |
+ | |||
+ | First stop the driver: | ||
/ | / | ||
Line 322: | Line 383: | ||
/ | / | ||
+ | ==== 5.3 Changing settings & other remote commands ==== | ||
+ | |||
+ | See here: https:// | ||
+ | |||
+ | That API allows to read and write VREGs. See MPPT, BMV and other HEX Protocol documents on our white paper section on the website for more information. Once you understood it all; its possible to reset a BMV too 100% with a one liner from the command line, ie "dbus -y com.victronenergy.battery.ttyO1 [find the right path] SetVreg [VREG] [DATA]. | ||
+ | |||
+ | The API will be used for a feature thats in progress: remotely changing settings of MPPTs, BMVs and other products connected to a GX device on the internet. | ||
===== 6. Screenshot ===== | ===== 6. Screenshot ===== | ||
open_source/ccgx/commandline.txt · Last modified: 2023-05-07 10:00 by mvader