energy-meters:et112
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
energy-meters:et112 [2019-08-15 12:47] – replace venus-device with GX device guy_stewart | energy-meters:et112 [2020-06-29 22:45] – [Option A: wireless Zigbee connection] added min. Venus version boekel | ||
---|---|---|---|
Line 56: | Line 56: | ||
Connect the Zigbee to RS485 converter to the ET112 energy meter: | Connect the Zigbee to RS485 converter to the ET112 energy meter: | ||
- | ^ Zigbee Converter ^ Energy meter ^ | + | ^ Zigbee Converter ^ Energy meter ^ Color ^ |
- | | GND | Terminal 6 | | + | | GND | Terminal 6 | Black | |
- | | A | Terminal 4 | | + | | A | Terminal 4 | Orange |
- | | B | Terminal 5 | | + | | B | Terminal 5 | Yellow |
| | ||
=== Step 3. === | === Step 3. === | ||
Line 67: | Line 67: | ||
Connect the 12V DC power supply to the Zigbee to RS485 converter. When the power is switched on, check the LEDs again. | Connect the 12V DC power supply to the Zigbee to RS485 converter. When the power is switched on, check the LEDs again. | ||
+ | === note on old and new zigbee converters === | ||
+ | Please note that there is a new zigbee converter available now, that is -not- backwards compatible with the old converters. If you have a non compatible set, please ask your supplier for a correct version. | ||
+ | |||
+ | ' | ||
+ | |||
+ | ASS300400100 - Zigbee to RS485 converter partnumber: DRF2619C | ||
+ | |||
+ | ASS300400100 - Zigbee to USB converter | ||
+ | |||
+ | ' | ||
+ | |||
+ | ASS300420100 - Zigbee to RS485 converter partnumber: DRF2659C | ||
+ | |||
+ | ASS300420200 - Zigbee to USB converter | ||
+ | |||
+ | |||
+ | |||
+ | == note on GX firmware versions: == | ||
+ | for the new type Zigbee converters, Venus OS v2.54 is the minimum required software version | ||