 ==== Introduction ==== ==== Introduction ====
-ModbusTCP is a feature on our [[venus-os:start|Venus-devices]] eg [[https://www.victronenergy.com/panel-systems-remote-monitoring/colorcontrol|Color Control GX]], and also the [[https://www.victronenergy.com/panel-systems-remote-monitoring/venus-gx|Venus GX]]. ModbusTCP is an industry standard protocol, that can be used to interface PLCs or other equipment with Victron products. For example to enable a heat pump when there is excess solar power, or create a fully integrated glass bridge on a yacht.+ModbusTCP is a feature on our [[venus-os:start|GX devices]] eg [[https://www.victronenergy.com/panel-systems-remote-monitoring/colorcontrol|Color Control GX]], and also the [[https://www.victronenergy.com/panel-systems-remote-monitoring/venus-gx|Venus GX]]. ModbusTCP is an industry standard protocol, that can be used to interface PLCs or other equipment with Victron products. For example to enable a heat pump when there is excess solar power, or create a fully integrated glass bridge on a yacht.
  
-Through the ModbusTCP interface you can read and write date to the chargers, battery monitors, inverter/chargers and other products connected to the Venus-device. The unit-id combined with the register address is used as a device-selector: selecting for example from which device you want to read its battery voltage measurement.+Through the ModbusTCP interface you can read and write date to the chargers, battery monitors, inverter/chargers and other products connected to the GX device. The unit-id combined with the register address is used as a device-selector: selecting for example from which device you want to read its battery voltage measurement.
  
 Besides reading this FAQ, make sure to also read the ModbusTCP section in our  [[https://www.victronenergy.com/upload/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf|Data communication whitepaper]]. Besides reading this FAQ, make sure to also read the ModbusTCP section in our  [[https://www.victronenergy.com/upload/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf|Data communication whitepaper]].
Line 37: Line 37:
 | com.victronenergy.temperature | Temperature sensors <sup>(1)</sup> | 3300 to 3305 | | com.victronenergy.temperature | Temperature sensors <sup>(1)</sup> | 3300 to 3305 |
  
-(1): Only the Venus GX is provided with temperature sensor inputs. The battery temperature as measured by a sensor connected to a VE.Bus device is not available. And the battery temperature as measured by a sensor connected to a BMV battery monitor is available under the com.victronenergy.battery register set.+(1): Check for compatible [[venus-os:start|GX devices]] (eg Venus GX) that provide temperature sensor inputs. The battery temperature as measured by a sensor connected to a VE.Bus device is not available. And the battery temperature as measured by a sensor connected to a BMV battery monitor is available under the com.victronenergy.battery register set.
  
 General note: not all list registers are available for each device. For example a BMV Battery Monitor has lots of readings: historical data such as maximum/minimum, for example. A canbus-connected lithium battery might not have those parameters available. General note: not all list registers are available for each device. For example a BMV Battery Monitor has lots of readings: historical data such as maximum/minimum, for example. A canbus-connected lithium battery might not have those parameters available.
Line 91: Line 91:
 ==== Advanced debugging ==== ==== Advanced debugging ====
  
-If all unit-id's and register-addresses have been checked and re-checked, and still the connection doesn't work, you could try looking at the modbustcp log file on the [[venus-os:start|Venus-device]]. +If all unit-id's and register-addresses have been checked and re-checked, and still the connection doesn't work, you could try looking at the modbustcp log file on the [[venus-os:start|GX device]]. 
  
 Follow these steps: Follow these steps:
Line 114: Line 114: