 ==== Introduction ==== ==== Introduction ====
-ModbusTCP is a feature on our [[https://www.victronenergy.com/panel-systems-remote-monitoring/colorcontrol|Color Control GX]], and also the [[https://www.victronenergy.com/panel-systems-remote-monitoring/venus-gx|Venus GX]]. ModbusTCP is an industry standard protocol, that can be used to interface PLCs or other equipment with Victron products. For example to enable a heat pump when there is excess solar power, or create a fully integrated glass bridge on a yacht.+ModbusTCP is a feature on our [[venus-os:start|Venus-devices]] eg [[https://www.victronenergy.com/panel-systems-remote-monitoring/colorcontrol|Color Control GX]], and also the [[https://www.victronenergy.com/panel-systems-remote-monitoring/venus-gx|Venus GX]]. ModbusTCP is an industry standard protocol, that can be used to interface PLCs or other equipment with Victron products. For example to enable a heat pump when there is excess solar power, or create a fully integrated glass bridge on a yacht.
  
 Besides reading this FAQ, make sure to also read the ModbusTCP section in our  [[https://www.victronenergy.com/upload/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf|Data communication whitepaper]]. Besides reading this FAQ, make sure to also read the ModbusTCP section in our  [[https://www.victronenergy.com/upload/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf|Data communication whitepaper]].
Line 89: Line 89:
 ==== Advanced debugging ==== ==== Advanced debugging ====
  
-If all unit-id's and register-addresses have been checked and re-checked, and still the connection doesn't work, you could try looking at the modbustcp log file on the Venus-device. +If all unit-id's and register-addresses have been checked and re-checked, and still the connection doesn't work, you could try looking at the modbustcp log file on the [[venus-os:start|Venus-device]]
  
 Follow these steps: Follow these steps:
Line 109: Line 109:
 Yes. See the [[https://www.victronenergy.com/live/system_integration:hub4_grid_parallel_external_control_loop|Hub-4 advanced control manual]] for more details. Yes. See the [[https://www.victronenergy.com/live/system_integration:hub4_grid_parallel_external_control_loop|Hub-4 advanced control manual]] for more details.
  