battery_compatibility:freedomwon
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | Next revisionBoth sides next revision | ||
battery_compatibility:freedomwon [2020-10-30 14:17] – Updated Venus OS for 2.60 warwickchapman | battery_compatibility:freedomwon [2020-11-28 15:12] – [CAN Bus Wiring] - added info for Cerbo boekel | ||
---|---|---|---|
Line 113: | Line 113: | ||
**Note:** In the case of the Venus GX or Octo GX, if the VE.CAN ports (RJ45) are being used by MPPTs, the secondary CAN bus needs to be connected using the green terminal blocks. | **Note:** In the case of the Venus GX or Octo GX, if the VE.CAN ports (RJ45) are being used by MPPTs, the secondary CAN bus needs to be connected using the green terminal blocks. | ||
+ | |||
+ | **Note:** When using a Cerbo GX use the ' | ||
If multiple batteries are installed in parallel the second RJ45 socket is used to link the next battery in the line onto the CAN Bus network. The termination resistor is installed in the last battery in the CAN Bus line. Refer to Lite installation manual for further information. | If multiple batteries are installed in parallel the second RJ45 socket is used to link the next battery in the line onto the CAN Bus network. The termination resistor is installed in the last battery in the CAN Bus line. Refer to Lite installation manual for further information. | ||
Line 198: | Line 200: | ||
☛ Settings → Services → VE.CAN port → CAN-bus Profile → CAN-bus BMS (500kbit/s) | ☛ Settings → Services → VE.CAN port → CAN-bus Profile → CAN-bus BMS (500kbit/s) | ||
- | //**Note**: For systems with VE Can MPPT' | + | //**Note**: For systems with VE Can MPPT' |
+ | All other GX devices have dual CAN-ports or a CAN-port that only supports 500kbit/s (GX version of inverters) so on those systems BMS-CAN should be set at 500kbps// | ||
{{ : | {{ : |
battery_compatibility/freedomwon.txt · Last modified: 2024-02-08 14:12 by warwickchapman