vrm_portal:faq
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | |||
vrm_portal:faq [2017-02-28 16:07] – [I want to analyze the data in a spreadsheet, how do I do this?] thlassche | vrm_portal:faq [2023-08-29 06:17] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 12: | Line 12: | ||
SOC stands for State of Charge. The BMV SOC is the state of charge measured by the BMV Battery Monitor. It calculates this value based on measurements taken by the shunt. And, assuming the shunt is installed in the correct place in the system, it takes into account all the loads and chargers. | SOC stands for State of Charge. The BMV SOC is the state of charge measured by the BMV Battery Monitor. It calculates this value based on measurements taken by the shunt. And, assuming the shunt is installed in the correct place in the system, it takes into account all the loads and chargers. | ||
- | The SOC taken from VE.Bus is calculated by our Multis and Quattros. To calculate the SOC, they use only the internally measured charge and discharge currents. Because of this you can only use it in a system | + | The SOC taken from VE.Bus is calculated by our Multis and Quattros. To calculate the SOC, they use only the internally measured charge and discharge currents. Because of this you can only use it for some system |
**BMV SOC vs VE.Bus SOC algorithm** | **BMV SOC vs VE.Bus SOC algorithm** | ||
- | See also [[ccgx:ccgx_faq#do_i_need_a_bmv_to_see_proper_battery_state_of_charge_or_not]] | + | See also [[https:// |
===== What are the requirements for the Solar yield and Consumption tab? ===== | ===== What are the requirements for the Solar yield and Consumption tab? ===== | ||
Line 30: | Line 30: | ||
{{ : | {{ : | ||
- | These graphs work on information calculated by the Color Control | + | These graphs work on information calculated by the GX device (Cerbo GX or Venus GX), based on energy counter values read from connected devices. |
General requirements: | General requirements: | ||
- | * Color Control | + | * [[venus-os: |
* Multi or Quattro with a 26 or 27 hardware: the 7 digit firmware number needs to start with 26 or 27. If it starts with 19 or 20, the product has old hardware. To get the consumption and solar yield tabs working for these products, the product needs to be replaced or get an control board upgrade. | * Multi or Quattro with a 26 or 27 hardware: the 7 digit firmware number needs to start with 26 or 27. If it starts with 19 or 20, the product has old hardware. To get the consumption and solar yield tabs working for these products, the product needs to be replaced or get an control board upgrade. | ||
* Multi or Quattro firmware needs to be recent as well: | * Multi or Quattro firmware needs to be recent as well: | ||
Line 45: | Line 45: | ||
* PV Inverter power and energy needs to be measured. For example a [[ccgx: | * PV Inverter power and energy needs to be measured. For example a [[ccgx: | ||
- | * There' | + | * There' |
* When using the AC Current Sensor, make sure to use the latest version of the Assistant, as released in October 2014. [[https:// | * When using the AC Current Sensor, make sure to use the latest version of the Assistant, as released in October 2014. [[https:// | ||
- | Other notes: | + | === 'Has DC system' |
+ | ‘Has DC system’ is a feature on a GX device. When that config switch is enabled, a new box called 'DC Power' appears on the GX display. Its value is calculated from the differential between the power measured by the bms or battery monitor, and the power flow measured by the inverter/ | ||
- | * DC consumption | + | * If this feature is enabled, and the used battery monitor is a BMV 700 or 712, then the minimum required BMV firmware version to make the VRM Energy dashboards operate correctly is v3.08. |
- | * A system with multiple | + | * The calculated value for 'DC Power' |
+ | |||
+ | === Other limitations === | ||
+ | * A system with multiple | ||
* Multiple AC current sensors measuring multiple PV inverters is supported as well. | * Multiple AC current sensors measuring multiple PV inverters is supported as well. | ||
- | * Other brands (not Victron) Solar Chargers | + | * These overviews work correctly when Victron Solar Chargers |
- | * The VGR, VGR2 and VER do not work: only the CCGX provides the necessary kWh data for these graphs. | + | * The VGR, VGR2 and VER do not provide any energy data data. |
- | * Combining MPPT Solar Chargers and PV Inverters in a system | + | * Combining MPPT Solar Chargers and PV Inverters in a system is supported. |
- | + | ||
- | ===== How does the device list work? Old products are still showing ===== | + | |
- | + | ||
- | This is the device list on the VRM Portal: | + | |
- | + | ||
- | {{: | + | |
- | It shows all products, their firmware version and some other additional information. After disconnecting a product from the Color Control GX or the Victron Global Remote, it is necessary to power cycle it (the CCGX or VGR). This will make the VRM Portal to empty the list and re-populate it based on the new information. | + | Note that the same data used to show these energy graphs |
===== How does the screensaver work? How is the displayed state determined? ===== | ===== How does the screensaver work? How is the displayed state determined? ===== | ||
Line 77: | Line 75: | ||
Please note: Safari is not downloading the files properly right now, please try Chrome or Firefox | Please note: Safari is not downloading the files properly right now, please try Chrome or Firefox | ||
+ | |||
===== How can I remove an installation from my account? ===== | ===== How can I remove an installation from my account? ===== | ||
Go to the tab Settings –> General and scroll to the bottom of that page, then click the ' | Go to the tab Settings –> General and scroll to the bottom of that page, then click the ' | ||
+ | |||
+ | ===== How can I move an installation' | ||
+ | |||
+ | You will need to connect the new GX device to the internet, and register it. Take note of the VRM Portal id. | ||
+ | |||
+ | Then open the old site on VRM, and go to **Settings** -> **General**. | ||
+ | |||
+ | There is an option there **Replace the GX device of this installation**. | ||
+ | |||
+ | This will explain the steps of the procedure. | ||
+ | |||
===== Why are some values shown red? ===== | ===== Why are some values shown red? ===== | ||
Line 85: | Line 95: | ||
In case the data is too old, which means older than would have been expected from the configured logging interval, the value will be shown red. Use the System overview page to check if there are products that are not connected anymore. One typical example where this might happen is: | In case the data is too old, which means older than would have been expected from the configured logging interval, the value will be shown red. Use the System overview page to check if there are products that are not connected anymore. One typical example where this might happen is: | ||
- | The system has been connected to a three phase system, and now it is connected to a single phase system. But the data for L2 and L3 is still being shown in a red color. Reboot the gateway (Color Control, Global Remote or Ethernet Remote) to reset the data. | + | The system has been connected to a three phase system, and now it is connected to a single phase system. But the data for L2 and L3 is still being shown in a red color. Reboot the gateway (Cerbo GX, Global Remote or Ethernet Remote) to reset the data. |
===== For how long is the data being stored? ===== | ===== For how long is the data being stored? ===== | ||
- | The data shown in the advanced tab is being stored for at least 6 months. The data used to show the solar yield and the consumption tab is stored 5 years minimum. | + | The data shown in the advanced tab is being stored for at least 6 months, with exception of Battery state of charge. |
+ | |||
+ | The data used to show the solar yield and the consumption tab (kWh data) is stored 5 years minimum. | ||
===== How can I zoom out any of the graphs? ===== | ===== How can I zoom out any of the graphs? ===== | ||
- | The graphs can be zoomed out to their original zoom level by clicking the 'Reset zoom' button in the graph. | + | The graphs can be zoomed out to their original zoom level by clicking |
===== Why do I get such a weird high value for AC Input when a PV inverter is feeding back to the grid through the Multi? ===== | ===== Why do I get such a weird high value for AC Input when a PV inverter is feeding back to the grid through the Multi? ===== | ||
Line 101: | Line 113: | ||
VGRs, VGR2s and VERs interpret this value incorrectly. They show around 650 Amps instead of -5 Amps. | VGRs, VGR2s and VERs interpret this value incorrectly. They show around 650 Amps instead of -5 Amps. | ||
- | If you really want to see the right data, replace the VGR/ | + | If you really want to see the right data, replace the VGR/ |
===== What is the column logtime Offset in the XLS/CSV download for? ===== | ===== What is the column logtime Offset in the XLS/CSV download for? ===== | ||
Line 109: | Line 121: | ||
The values relate to the backlog feature. Usually the column is either empty, or you see series of rows with a decreasing logtime offset. Once zero, the columns are empty again. These series mean that there was a problem with the Internet connection. And the value shown is the number of seconds for which that particular row of data had been backlogged. | The values relate to the backlog feature. Usually the column is either empty, or you see series of rows with a decreasing logtime offset. Once zero, the columns are empty again. These series mean that there was a problem with the Internet connection. And the value shown is the number of seconds for which that particular row of data had been backlogged. | ||
+ | ===== How can I change my email address, or add new additional users? ===== | ||
+ | |||
+ | Login to VRM with the existing account, invite the new email address (Settings -> Users -> Invite). {{: | ||
+ | |||
+ | If the new user will be an Admin, you will need to enable full control. | ||
+ | |||
+ | That is all, there will be an email sent to the new email address and you can use that to login. | ||
+ | |||
+ | There is no option to delete the old account, though it can be removed from a specific installation. | ||
+ | |||
+ | No data will be lost during this procedure. | ||
+ | |||
+ | ===== How can I upload very large database files to the VRM with a 200MB upload limit? ===== | ||
+ | The VRM Portal only allows up to 200MB uploads for GX device data files. The portal will accept gzip files, so you can compress the databases and then upload those. A compressed 200MB file can contain up to a year or more worth of data! | ||
+ | |||
+ | ===== I have just connected my GX device after not being online for a long time, why is it not updating? ===== | ||
+ | |||
+ | The first thing to check is the VRM menu to make sure that the VRM is connected and communicating - if it isn't, follow the [[https:// | ||
+ | |||
+ | If you are seeing that the GX device is connecting to VRM, then it can take up to a few hours or more for the data to sync to VRM and for the updates to show, depending on how much data there is to catch up. If it still has not got up to date after 24 hours of connection time - try asking for more help on http:// | ||
+ | |||
+ | ===== Why can't I get push notifications in my Chrome browser on a Apple Mac? ===== | ||
+ | |||
+ | There are two possible reasons why you don't receive notifications: | ||
+ | - Chrome is not allowed to show notifications on macOS | ||
+ | - Chrome has disabled notifications in the app settings | ||
+ | Allow Chrome to send notifications to the macOS Notification Center by opening System Preferences -> Notifications in macOS. Then scroll down to Google Chrome and turn on "Allow notifications" | ||
- | ===== DISQUS ===== | + | Also make sure Notifications are enabled in the Chrome app settings (in the Chrome app go to Settings -> Content -> Notifications) and the VRM domain is allowed to send notifications. Check out [[https:// |
- | ~~DISQUS~~ | + |
vrm_portal/faq.txt · Last modified: by guy_stewart