victronconnect:mppt-solarchargers [2019-12-12 17:32] tabreuvictronconnect:mppt-solarchargers [2020-02-03 14:42] tabreu
Line 54: Line 54:
 (If you are operating an [[http://https://www.victronenergy.com/live/ess:design-installation-manual|ESS]] (Energy Storage System) the charge time for this will be included in the 'Bulk' reading.)  (If you are operating an [[http://https://www.victronenergy.com/live/ess:design-installation-manual|ESS]] (Energy Storage System) the charge time for this will be included in the 'Bulk' reading.) 
  
-It is possible to export the history by clicking the three connected dots at the top right of the history screen. +It is possible to export the history as a comma separated file (.csv) by clicking the three connected dots at the top right of the history screen
 + 
 +{{:victronconnect:history_export.jpg?direct&175|}} 
 + 
 +This is an example of the exported data for 3 of 30 days: 
 + 
 +^Days ago^Yield(Wh)^Max. PV power(W)^Max. PV voltage(V)^Min. battery voltage(V)^Max. battery voltage(V)^Time in bulk(m)^Time in absorption(m)^Time in float(m)^Last error^2nd last error^3rd last error^4th last error^ 
 +|0|14500|2167|118.80|51.34|52.99|748|0|0|0|0|0|0| 
 +|1|15450|2326|118.81|51.68|53.97|869|0|0|0|0|0|0| 
 +|2|12350|2925|126.67|51.73|55.42|872|0|0|0|0|0|0| 
 + 
 + 
  
 **Battery Voltage**\\  **Battery Voltage**\\ 
Line 190: Line 202:
 The configured coefficient is in mV per degree Celsius for the whole battery bank, not per cell. The base temperature for the compensation is 25°C (77°F), as shown in the chart below. The configured coefficient is in mV per degree Celsius for the whole battery bank, not per cell. The base temperature for the compensation is 25°C (77°F), as shown in the chart below.
  
-{{ :victronconnect:temperature_compensation_internal.png?350|Battery voltage adjustment based on internal temperature measurement}}+{{:victronconnect:tempcomp_-graph.png?350|Battery voltage adjustment based on battery temperature (14.4V as setpoint, compensation factor = 16.2mV/ºC)}}
  
 With a [[:smart_battery_sense_manual|Smart Battery Sense]] is installed; the actual battery temperature will be used for compensation; throughout the day. With a [[:smart_battery_sense_manual|Smart Battery Sense]] is installed; the actual battery temperature will be used for compensation; throughout the day.