User Tools

Site Tools


victronconnect:beta

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
victronconnect:beta [2026-09-01 17:17] – mpalavecinovictronconnect:beta [2026-11-10 13:33] (current) – [v6.43 (Released officially)] jperez
Line 11: Line 11:
 (Currently available betas are on top. See further below for official releases.) (Currently available betas are on top. See further below for official releases.)
  
-==== v6.50beta4 ==== + 
-** 2026-08-31 **+==== v6.50beta13 ==== 
 +** 2026-10-27 **
  
 __Download links:__ __Download links:__
Line 21: Line 22:
     * [[https://groups.google.com/g/victronconnect-beta-testing|1. Join beta testing group on this link ]]     * [[https://groups.google.com/g/victronconnect-beta-testing|1. Join beta testing group on this link ]]
     * [[https://play.google.com/apps/testing/com.victronenergy.victronconnect|2. Join VictronConnect beta on Google Play Store ]]     * [[https://play.google.com/apps/testing/com.victronenergy.victronconnect|2. Join VictronConnect beta on Google Play Store ]]
-  * [[https://www.dropbox.com/scl/fi/hu4z4fumomankl3fwfhwe/VictronConnectInstaller.exe?rlkey=m70nf7nvygk7oprus8lkqfrj7&st=jey827ya&dl=1|Windows 10 and higher]] +  * [[https://www.dropbox.com/scl/fi/1q981eh043zau6ukrh4ut/VictronConnectInstaller.exe?rlkey=ttps7xwplgejaddlgr0k5ygqk&st=j2zmb7jl&dl=1|Windows 10 and higher]] 
-  * [[https://www.dropbox.com/scl/fi/xyud4373o53dm8ofj4og9/VictronConnect.dmg?rlkey=c5kj02ydcw69ubkt3ozv88yte&st=alnor9pq&dl=1|macOS 11 (Big Sur) and higher]] +  * [[https://www.dropbox.com/scl/fi/58qj08qhtfq75sssbixoa/VictronConnect.dmg?rlkey=jjx9v78er5knhm5fdi2gc3ruh&st=gpx29fms&dl=1|macOS 11 (Big Sur) and higher]] 
-  * [[https://www.dropbox.com/scl/fi/fmkr1gwiua7org1798jsl/VictronConnect-x86_64.AppImage?rlkey=tt26fwkzegjeqxlvoqrvyjd09&st=epa3ziwd&dl=1|Linux AppImage]]+  * [[https://www.dropbox.com/scl/fi/w49stgb7jvat9cmomgak9/VictronConnect-x86_64.AppImage?rlkey=06p7loww4ygio9h71zzohkir5&st=zsibjkkv&dl=1|Linux AppImage]]
  
 Please report bugs and give feedback to these betas via the Disqus comments below. Please note that comments are not public by default, and first go to a moderation queue. Please report bugs and give feedback to these betas via the Disqus comments below. Please note that comments are not public by default, and first go to a moderation queue.
 +
 +__Changes__
 +
 +Remote Console
 +  * Added a "No internet connection" message with a Retry button when the phone is offline
 +  * The remote console now always loads the version that matches the GX, including after firmware updates or downgrades
 +  * Fixed a verification issue after signing in to a password-protected GX device
 +  * Fixed an occasional crash while synchronizing product PINs with VRM
 +
 +Android
 +  * In full-screen mode, system bars no longer reappear with every touch on older Android versions
 +  * Improved use of the display area around the front camera on older Android versions
 +
 +Apple CarPlay
 +  * Products are now displayed even when the phone is locked or when the app is started from the car
 +  * Each product now shows its two most important values without rotating between values
 +  * Removed the "Unlock your phone" message
 +  * Fixed crashes that could occur when unlocking the phone while CarPlay is active
 +  * Improved stability with fewer unnecessary screen refreshes and no more stuck alerts
 +
 +
 +
 +==== v6.50beta12 ====
 +** 2026-10-23 **
 +
 +__Changes__
 +
 +VRM
 +  * Android: VRM sign-in now supports passkeys
 +  * macOS: Signing in to VRM no longer uses a previous session
 +  * Improved VRM loading and error screens
 +  * Improved reliability when loading VRM pages after signing in
 +
 +Remote Connection
 +  * Improved remote reconnection behavior when returning to the app
 +  * Opening the app without an internet connection no longer shows a connection error; installations appear automatically once connectivity is restored
 +
 +GlobalLink & P1 Link
 +  * GlobalLink: Mobile operator information is shown again
 +  * GlobalLink: Renamed "Smart Devices" to "External Devices"
 +  * P1 Link: "Last seen" now shows "a few seconds ago" for recent updates
 +  * Removed the energy counter reset option from P1 Link
 +  * Removed the VRM information pop-up from GlobalLink and P1 Link settings
 +
 +EV Charging Station
 +  * Added firmware v1.02 for V2 models
 +
 +Other
 +  * Fixed overlapping text in value rows
 +  * Improved firmware release checking
 +  * Fixed EVCS demo issues introduced in v6.50beta11
 +
 +==== v6.50beta11 ====
 +** 2026-10-16 **
  
 __Changes__ __Changes__
  
 General General
-  * Improved overall performance +  * Added support for future products
-  * Fixed a crash that could occur when loading saved settings files for certain products +
-  * Fixed incorrect timestamps when exporting CSV trend data in regions with negative UTC offsets+
  
-Windows +SuperPack NG 
-  * Fixed an issue where a VictronConnect process could remain running in the background under certain circumstances+  * Added "Always Off" heater mode setting (requires an upcoming firmware release) 
 +  * Added a new "External Feedback Signal" setting that allows the external signal to be used as an alarm (requires an upcoming firmware release) 
 +  * Added charge/discharge off reasons #14 "Cell Measurement Fault" and #15 "Long Charging Protection" (requires an upcoming firmware release)
  
 EVCS EVCS
-  * Added support for upcoming features that require a future firmware release+  * Added support for "Control Charging by Tag" (EVCS V2 only — requires an upcoming firmware release) 
 +  * Added support for new first-setup configurations (requires an upcoming firmware release) 
 +  * Fixed several issues with scheduler settings 
 +  * Various other fixes and improvements
  
-Lynx Smart BMS 
-  * Added more detailed information when charging or discharging is not allowed (Requires a future firmware release). 
-  * Added support for new alarms introduced in a future firmware release 
  
-MultiRS +==== v6.50beta10 ==== 
-  * Add firmware v1.32 for Multi RS Smart 48/6000+** 2026-10-06 **
  
 +__Changes__
  
-==== v6.41 (Released officially) ==== +General 
-** 2026-08-25 **+  * Added support for future products
  
-__Download links:__+GX Remote Console 
 +  * Various improvements
  
-  * iOS: [[https://itunes.apple.com/app/victronconnect/id943840744?mt=8|App Store]] +SmartShunt 
-  * [[https://play.google.com/store/apps/details?id=com.victronenergy.victronconnect|Android]] +  * Added firmware v4.20
-  * [[http://updates.victronenergy.com/feeds/VictronConnect/windows/w10/VictronConnectInstaller.exe|Windows 10 and higher]] +
-  * macOS [[https://itunes.apple.com/app/victronconnect/id1084677271?mt=12|11 (macOS Big Sur) and higher|App Store]] +
-  * [[https://updates.victronenergy.com/feeds/VictronConnect/linux/VictronConnect-x86_64_v6.41.AppImage|Linux AppImage]]+
  
-Firmware updates: For more details, check release notes on Victron Professional.+BMV 712 
 +  * Added firmware v4.20 
 + 
 + 
 +==== v6.50beta9 ==== 
 +** 2026-09-30 **
  
 __Changes__ __Changes__
  
-General +Installation page (VRM) 
-  * Improve batch programming robustness+  * Reduced dashboard loading time 
 +  * Improved loading state UI 
 +  * Improved retry mechanism in case of network failure 
 + 
 +GX Remote Console 
 +  * Fix a bug that makes it not loading after resuming the app 
 + 
 +MPPT RS 
 +  * Added error #41, "PV isolation failure" (requires an upcoming firmware release) 
 + 
 +SuperPack NG 
 +  * Fixed Min/Max Temperature values not being displayed properly 
 + 
 +EVCS 
 +  * Added firmware v2.09 
 + 
 +OrionXS 
 +  * Added firmware v1.15 
 + 
 +SolarSense 
 +  * Fixed an issue when setting the device RTC under certain conditions 
 + 
 +==== v6.50beta8 ==== 
 + 2026-09-18  
 + 
 +__Changes__ 
 + 
 +iOS 
 +  * Add Apple CarPlay support. (Bluetooth)
  
 Android Android
-  * Improve battery usage for home screen widgets and alarm notifications. +  * Improve Bluetooth device scanning 
-  * Fix Android reporting VictronConnect as crashing in the background on some phones.+  * Notify when Bluetooth scanning cannot be initiated 
 + 
 +GX Remote Console 
 +  * Significantly improve loading time
  
 EVCS EVCS
- * Various improvements+  * Add new errors and warnings 
 +  * Add local firmware updates via Ethernet (EVCS V2 only — requires a future firmware release) 
 +  * Add Instant Readout support for remote connections
  
-BMV/SmartShunt +MultiHS 
-  * Fix manual SOC setting when the reported SOC is undefined+  * Fix Grid Feed-In settings visibility
  
-Lynx SmartBMS 
-  * Add support for new alarms to be introduced in a future firmware release 
  
-MPPT Solar Chargers: + 
-  * Add firmware v1.75 for some models+ ==== v6.50beta7 ==== 
 + 2026-09-14  
 + 
 +__Changes__ 
 + 
 +EVCS 
 +  * Add firmware v2.08 
 + 
 +OrionXS 
 +  * Further improvements to the Emergency Charge feature (requires a future firmware release) 
 + 
 +==== v6.50beta6 ==== 
 +** 2026-09-11 ** 
 + 
 +__Changes__ 
 + 
 +General 
 +  * Enable VRM data tabs on locally connected GX devices 
 +  * List GlobalLink installations alongside GX remote installations (VRM tab) 
 +  * Make it possible to create a VRM installation directly from VictronConnect 
 +  * Add VRM account creation in the Remote tab and Settings 
 +  * Add VRM login directly within VictronConnect 
 +  * Speed up Remote Console loading after the first load 
 +  * Various UI wording improvements as part of the continued VRM integration in VictronConnect 
 + 
 +OrionXS 
 +  * Further improvements to the Emergency Charge feature (requires a future firmware release) 
 + 
 +MultiHS 
 +  * Hide certain not yet supported settings 
 + 
 + 
 +==== v6.50beta5 ==== 
 +** 2026-09-3 ** 
 + 
 +__Changes__ 
 + 
 +General 
 +  * Improved overall performance 
 + 
 +OrionXS 
 +  * Improved the Emergency Charge feature (requires a future firmware release) 
 + 
 + 
 +==== v6.50beta4 ==== 
 +** 2026-08-31 ** 
 + 
 +__Changes__ 
 + 
 +General 
 +  * Improved overall performance 
 +  * Fixed a crash that could occur when loading saved settings files for certain products 
 +  * Fixed incorrect timestamps when exporting CSV trend data in regions with negative UTC offsets 
 + 
 +Windows 
 +  * Fixed an issue where a VictronConnect process could remain running in the background under certain circumstances 
 + 
 +EVCS 
 +  * Added support for upcoming features that require a future firmware release 
 + 
 +Lynx Smart BMS 
 +  * Added more detailed information when charging or discharging is not allowed (Requires a future firmware release). 
 +  * Added support for new alarms introduced in a future firmware release 
 + 
 +MultiRS 
 +  * Add firmware v1.32 for Multi RS Smart 48/6000 
  
 ==== v6.50beta3 ==== ==== v6.50beta3 ====
Line 137: Line 293:
 MultiHS MultiHS
   * Added support for PV Tracker enabling settings   * Added support for PV Tracker enabling settings
 +
 +
 +==== v6.43.1 (Released officially) ====
 +** 2026-11-10 **
 +
 +This version is only available for Windows, macOS, Android and Linux.
 +
 +__Download links:__
 +
 +  * [[https://play.google.com/store/apps/details?id=com.victronenergy.victronconnect|Android]]
 +  * [[https://updates.victronenergy.com/feeds/VictronConnect/windows/w10/VictronConnectInstaller.exe|Windows 10 and higher]]
 +  * macOS [[https://itunes.apple.com/app/victronconnect/id1084677271?mt=12|13 (macOS Ventura) and higher|App Store]]
 +  * [[https://updates.victronenergy.com/feeds/VictronConnect/linux/VictronConnect-x86_64_v6.43.1.AppImage|Linux AppImage]]
 +
 +Firmware updates: For more details, check release notes on Victron Professional.
 +
 +__Changes__
 +
 +
 +VE.Bus Inverter/Chargers
 +  * Improved VE.Bus Inverter/Charger firmware updates
 +  * Added firmware v568 and v570
 +
 +==== v6.43 (Released officially) ====
 +** 2026-09-23 **
 +
 +__Changes__
 +
 +OrionXS
 +  - Added firmware v1.15
 +  - Added the new "Emergency Charge" feature
 +
 +
 +==== v6.42 (Released officially) ====
 +** 2026-09-09 **
 +
 +__Changes__
 +
 +Lynx Smart BMS
 +- Added more detailed information when charging or discharging is not allowed (Requires a future firmware release).
 +- Added support for new alarms introduced in a future firmware release
 +
 +Android
 +- Fixed an issue where the device list could remain empty under certain conditions on some Android devices and versions.
 +
 +iOS
 +- Improved battery usage on recent versions of iOS
 +
 +
 +==== v6.41 (Released officially) ====
 +** 2026-08-25 **
 +
 +__Changes__
 +
 +General
 +  * Improve batch programming robustness
 +
 +Android
 +  * Improve battery usage for home screen widgets and alarm notifications.
 +  * Fix Android reporting VictronConnect as crashing in the background on some phones.
 +
 +EVCS
 + * Various improvements
 +
 +BMV/SmartShunt
 +  * Fix manual SOC setting when the reported SOC is undefined
 +
 +Lynx SmartBMS
 +  * Add support for new alarms to be introduced in a future firmware release
 +
 +MPPT Solar Chargers:
 +  * Add firmware v1.75 for some models
  
  
victronconnect/beta.1788283062.txt.gz · Last modified: by mpalavecino

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki