victronconnect:beta
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| victronconnect:beta [2025-07-18 23:22] – [v6.20beta14] jperez | victronconnect:beta [2025-10-27 12:31] (current) – mpalavecino | ||
|---|---|---|---|
| Line 11: | Line 11: | ||
| (Currently available betas are on top. See further below for official releases.) | (Currently available betas are on top. See further below for official releases.) | ||
| - | ==== v6.20beta15 | + | ==== v6.30beta2 |
| - | ** 2025-07-18 ** | + | ** 2025-10-27 ** |
| __Download links:__ | __Download links:__ | ||
| * iOS: [[https:// | * iOS: [[https:// | ||
| - | * [[https:// | + | * [[https:// |
| - | * [[https:// | + | * [[https:// |
| - | * [[https:// | + | * [[https:// |
| - | * [[https:// | + | * [[https:// |
| - | * [[https:// | + | * [[https:// |
| Notes: | Notes: | ||
| Line 30: | Line 30: | ||
| __Changes__ | __Changes__ | ||
| - | * General performance improvements | + | Online Firmware Library |
| + | | ||
| - | Lynx Shunt VE.Can | + | ==== v6.30beta1 |
| - | * Fix " | + | ** 2025-10-08 ** |
| - | + | ||
| - | VRM Installations: | + | |
| - | * Handling installations as " | + | |
| - | * Installations are presented in two sections: " | + | |
| - | * Set/Unset as Favorites option is added | + | |
| - | + | ||
| - | Inverter, Multi RS: | + | |
| - | * Add " | + | |
| - | * Disable the Ground relay when the Grid Code has the 'AC Neutral path externally joined' | + | |
| - | * Fixes on data reads when System phase is L2 or L3 | + | |
| - | + | ||
| - | EVCS | + | |
| - | * Add more detailed info when the product can't be reached via local network for firmware updates | + | |
| - | * Add control on the password length | + | |
| - | + | ||
| - | MPPT Solar Chargers: | + | |
| - | * Add firmware v1.68 | + | |
| - | * Remove battery temperature compensation from load output voltage thresholds | + | |
| - | + | ||
| - | + | ||
| - | ==== v6.20beta14 | + | |
| - | ** 2025-07-08 ** | + | |
| __Changes__ | __Changes__ | ||
| - | | + | Energy Meter VM-3P75CT |
| + | | ||
| + | * Increase robustness of CAN-bus handling to avoid brief passthrough mode occurrences in MultiRS systems | ||
| - | VictronConnect-remote: | + | EVCS |
| - | * Improve connection and fetching times | + | * Add firmware v2.05: |
| - | * Fix an error that can make connection stuck at 40% and finally report an error while getting the products list | + | * Minor stability |
| - | * Various robustness | + | |
| - | * Order products list by name | + | |
| - | GX: | + | InverterRS & MultiRS: |
| - | * Fix remote console button is not shown when GUI v2 is the default one | + | * Fix a bug that makes VictronConnect crash when load settings saved with VictronConnect 6.19 and older |
| - | VE.Bus inverter/ | + | Small & VEBus BMS |
| - | * Add support for remote connection via VRM and local network. Monitoring only. | + | * Updated history temperature description |
| SolarSense | SolarSense | ||
| - | * Add data selection for historical values | + | * Fix Total yield in the period on History page which caused that one of the days was summed twice |
| - | * Add total estimated energy | + | |
| - | * Add graphics for historical values | + | |
| - | * Add instant readout | + | |
| - | * Fix instant readout total yield | + | |
| - | Energy Meter: | + | General |
| - | | + | * Fix numeric input validator showing wrong input when language/region |
| - | + | ||
| - | MPPT Solar Chargers: | + | |
| - | * Fix some models do not export TX/RX settings to settins files | + | |
| - | + | ||
| - | Inverter, Multi RS: | + | |
| - | * Add firmware v 1.25 | + | |
| - | * For Inverter RS and Multi RS: | + | |
| - | * Add warning #76: shown when the inverter shuts down during operation due to insufficient inverters in the group. | + | |
| - | * Increase AC PV inverter stop frequency to 53.2Hz | + | |
| - | * For Multi RS working in 3 phase configurations and/or parallel configurations only: | + | |
| - | * Add settings synchronisation, | + | |
| - | * Add ' | + | |
| - | * Various improvements | + | |
| - | * Changes specific for Germany: | + | |
| - | * Add 3-phase support. | + | |
| - | * Divide maximum charge power 4.2kW by the number of units if the charge restriction is active | + | |
| - | + | ||
| - | EVCS | + | |
| - | * Add firmware v2.03 | + | |
| - | * Reduced the voltage drop threshold for detecting a connected EV during the CP auto-calibration procedure | + | |
| - | * Fixed an issue with 2s delay before power off in disconnected state | + | |
| - | * Fixed an issue in the CP auto-calibration procedure that caused calibration to occur in a disconnected state | + | |
| - | * Fix color manual input selection for lightring settings | + | |
| - | SmartCharger: | + | Qt Framework Upgrade: We transition from Qt 6.5 to Qt 6.8. This update brings improvements and advantages that enhance the user experience and set the stage for new features in the future. |
| - | * Add mode button lock option | + | |
| - | ==== v6.20beta13 | + | ==== v6.23 (Released officially) |
| - | ** 2025-06-11 ** | + | ** 2025-10-20 ** |
| __Download links:__ | __Download links:__ | ||
| - | * iOS: Join TestFlight https:// | + | * iOS: [[https://itunes.apple.com/app/victronconnect/id943840744?mt=8|App Store]] |
| - | * [[https://www.dropbox.com/scl/fi/gmopj9ts7jum4n1b2otwn/ | + | * [[https://play.google.com/store/apps/details? |
| - | * [[https://www.dropbox.com/scl/fi/h7m5ymzhhjjjdjdv1c03a/ | + | * [[http://updates.victronenergy.com/feeds/ |
| - | * [[https://www.dropbox.com/scl/fi/0rmcduskhe7khn9653zl1/ | + | * macOS [[https://itunes.apple.com/app/victronconnect/id1084677271?mt=12|11 (macOS Big Sur) and higher|App Store]] |
| - | * [[https://www.dropbox.com/scl/fi/up3ak71ao72q35goxez4c/ | + | * [[https:// |
| - | * [[https:// | + | |
| Notes: | Notes: | ||
| Line 128: | Line 78: | ||
| __Changes__ | __Changes__ | ||
| - | * Fix spin box switch dialog size | + | * Fix numeric input values are not correctly validated |
| - | * Save some space for the graphics of solar charger history data on full screen mode | + | |
| - | Multi RS: | + | EVCS: |
| - | * Add " | + | * Add firmware v2.05 |
| - | * Add " | + | |
| - | * Some fixes at "Ac input control" | + | |
| - | SolarSense | + | Energy Meter: |
| - | * Add Long History support & show historical maximums | + | * Add firmware v1.11 |
| - | * Fix Instant Readout | + | |
| - | MultiHS | + | Lynx Shunt: |
| - | * Add settings save definition | + | * Improve calibration routine |
| - | + | ||
| - | GlobalLink: | + | |
| - | * Add support for rev2 hardware | + | |
| - | + | ||
| - | ==== v6.20beta12 ==== | + | |
| - | ** 2025-05-26 ** | + | |
| - | + | ||
| - | + | ||
| - | __Changes__ | + | |
| - | + | ||
| - | Orion Smart: | + | |
| - | * Fix startup issue on 48V output smart models | + | |
| - | + | ||
| - | SmallBMS NG: | + | |
| - | * Various improvements | + | |
| - | + | ||
| - | VE.Bus BMS NG: | + | |
| - | * Various improvements | + | |
| - | + | ||
| - | SuperPack NG: | + | |
| - | * Add initial support | + | |
| - | + | ||
| - | SmartSolar: | + | |
| - | * Add Bluetooth firmware v2.53: | + | |
| - | * Add VE.Smart Networking support for SmartSolar 250|60 & 250|70 | + | |
| - | + | ||
| - | Phoenix & SUN inverter: | + | |
| - | * Add firmware v1.37: | + | |
| - | * Add missing high DC ripple voltage / high DC terminal temperature alarm and warning | + | |
| - | * Add support for new models | + | |
| - | + | ||
| - | Smart Charger IP22, IP43 & IP65: | + | |
| - | * Add lock mode button option. This feature requires a new firmware that will be released soon. | + | |
| - | + | ||
| - | ==== v6.20beta11 ==== | + | |
| - | ** 2025-04-25 ** | + | |
| - | + | ||
| - | __Changes__ | + | |
| - | * Android: Fix custom names are not updated in the product list on some Android versions | + | |
| - | * Fix Android navigation buttons don't work from the firmware update page in some situations | + | |
| - | + | ||
| - | SmartShunt & BMV-712: | + | |
| - | * Add firmware v4.19: | + | |
| - | * Added setting (76) to reverse the shunt direction (signedness of the Current will swap i.e. postive current becomes negative and vice versa). | + | |
| - | * Support battery capacity up to 32500 Ah (prior limit was set to 9999 Ah). | + | |
| - | + | ||
| - | OrionXS: | + | |
| - | * Add firmware v1.11: | + | |
| - | * Internal improvements | + | |
| - | * Fix Orion XS 1400 Smart Alternator(24V) preset | + | |
| Multi RS: | Multi RS: | ||
| - | * Add Czech grid code (not in firmware yet) | + | * Fix settings saved with v6.19 or earlier could fail to load |
| - | Skilla-i: | + | VE.Bus Inverter/ |
| - | * Hide AC input current limit setting on models | + | * Add new MultiPlus-II |
| - | EVCS: | ||
| - | * Add firmware v2.02: | ||
| - | * Added CP line auto-calibration procedure. Activated by default | ||
| - | * Added retries for FW update over the web interface in case of error | ||
| - | * Added more warning messages related to display FW update | ||
| - | * Improvements for auto mode, related to start by low excess power and start by battery maximum SoC | ||
| - | * Fixed issue with special characters in WiFi SSID | ||
| - | * Fixed issue with display firmware storage | ||
| - | * Improve firmware update mechanism | ||
| - | * Fix connection issues on firmware v1.24 & v1.25 | ||
| - | * Add new warnings and errors notifications | ||
| - | ==== v6.20beta10 | + | ==== v6.22 (Released officially) |
| - | ** 2025-04-12 ** | + | ** 2025-09-23 ** |
| __Changes__ | __Changes__ | ||
| - | * Various improvements to reduce the chance of getting a crash report when closing VictronConnect | ||
| - | * Fix an issue where VictronConnect could freeze for a while when opening a VRM deep link, if the app was not already running. | ||
| + | GX: | ||
| + | * Fix an issue where remote products are not displayed under certain conditions on Venus versions older than v3.50 | ||
| + | * Fix an issue where a blank page is displayed on Venus versions older than v3.50 when VRM two-way communication is disabled | ||
| - | MPPT RS, Inverter RS: | + | VE.Bus Inverter/ |
| - | * Add firmware v1.22: | + | * Update |
| - | * Changes applying to all RS models: | + | * Depending the model the latest |
| - | * Fix Paygo issue | + | |
| - | * Changes applying to all RS models: | + | |
| - | * Fix Paygo issue. | + | |
| - | * Changes applying to the Inverter | + | |
| - | * History does not log incoming AC power if there is no PV inverter detected. | + | |
| - | * Changes applying to Multi RS only: | + | |
| - | * Add grid codes: Germany single phase, South Africa and Spain Storage Systems without feed-in surplus. | + | |
| - | * Improve stability of 3 phase systems when connecting to the ac input.* | + | |
| - | * Improvements on display settings menu | + | |
| - | * Add Solar charger On/Off control | + | |
| - | + | ||
| - | Multi RS: | + | |
| - | * Add new and improve existing off reasons | + | |
| - | * Improvemets on display settings menu | + | |
| - | * Add firmrmware v1.23: | + | |
| - | * Fix storing the grid code specific settings in non-volatile memory. | + | |
| - | * Note when upgrading from v1.22: please check the grid settings in VictronConnect, | + | |
| - | + | ||
| - | Orion XS: | + | |
| - | * Fix generator shut-down detection can show wrong selected preset | + | |
| - | * Remember last selected values for trends | + | |
| - | * Fix connection via VE.Direct cable | + | |
| - | * Fix some settings are not available via remote connections | + | |
| - | + | ||
| - | Smart Charger IP43: | + | |
| - | * Fix connection via VE.Direct cable | + | |
| - | * Fix some settings are not available via remote connections | + | |
| - | + | ||
| - | MPPT Solar Chargers: | + | |
| - | * Add firmware | + | |
| - | * Internal improvements for SmartSolar 100/ | + | |
| - | * Improve startup robustness when a running on a synchronized charging network. | + | |
| - | * Improve robustness of 100/50 startup under high solar potential. | + | |
| - | + | ||
| - | smallBMS NG: | + | |
| - | * Fix demo library icon | + | |
| - | * Add firmware | + | |
| - | * Reduced power consumption | + | |
| - | + | ||
| - | + | ||
| - | Energy Meter: | + | |
| - | * Add power factor live data | + | |
| - | * Add phase sequence live data | + | |
| - | * Add phase rotation alarm | + | |
| - | + | ||
| - | EVCS: | + | |
| - | * Add description to various notifications, errors and warnings | + | |
| - | * Add Light Ring brightness limit settin (to be included in future firmware releases) | + | |
| - | + | ||
| - | ==== v6.20beta9 ==== | + | |
| - | ** 2025-04-01 ** | + | |
| - | + | ||
| - | + | ||
| - | __Changes__ | + | |
| - | * Update translations | + | VE.Bus Smart Dongle: |
| - | * Fix VE.Direct | + | * Fix AC output instant readout |
| - | * Various internal improvements | + | |
| Multi RS: | Multi RS: | ||
| - | * Fix an issue that makes the solar trackers | + | * Allow battery presets |
| - | ==== v6.20beta8 | + | ==== v6.21 (Released officially) |
| - | ** 2025-03-25 ** | + | ** 2025-09-18 ** |
| __Changes__ | __Changes__ | ||
| - | VRM deep links: | + | VE.Bus Inverter/Chargers: |
| - | Connect to remote products in VictronConnect directly from the VRM devices list by clicking the 'Open in VictronConnect' | + | * Fix detailed view is not loaded when connecting via MK3 |
| - | [[https:// | + | |
| - | * Actually fix an issue where, in some situations, VictronConnect incorrectly reports the installation as offline when the user tries to connect via deep links. | + | VE.Bus Smart Dongle: |
| + | * Fix settings button is not visible | ||
| - | Multi RS: | + | EVCS: |
| - | * Add option to configure Aux input 2 to imit the installation battery charge power to 4.2kW (German grid code only) | + | * Add firmware v2.04: |
| - | * Add new alarms: | + | * Added " |
| - | * Grid lost | + | * Improvements to meet cybersecurity requirements |
| - | * Phase configurations | + | * Improvements in Grid ON/OFF state detection |
| - | * Energy meter missing | + | * Improvements in handling ' |
| + | * Fixed an issue causing a 2-second delay before power-off in the charged state | ||
| + | * Fixed incorrect Gateway address in Wi-Fi AP mode | ||
| + | |||
| + | ==== v6.20 (Released officially) ==== | ||
| + | 2025-09-17 | ||
| - | MPPT RS, Inverter RS Solar & Multi RS: | + | **Changes** |
| - | | + | |
| - | smallBMS NG: | + | General improvements |
| - | * Add firmware v1.02: | + | * Various performance and stability improvements |
| - | * Added product reset at (soft) switch ON | + | * Add copy action for Serial Number on Product Info page |
| - | * Resolved issues with SoC & History update | + | * Numeric setting inputs UX improvements |
| - | * Add demo product | + | * Text inputs |
| + | * Fix Instant Readout showing the same data for two products in certain cases | ||
| + | * Fix an issue that makes impossible to select a manual added firmware file in certain situations | ||
| - | VE.Bus Inverter/ | + | VRM Installations |
| - | * Add firmware v556: | + | |
| - | * Fixes instability issues (during PowerAssist/ | + | |
| - | + | ||
| - | + | ||
| - | ==== v6.20beta7 ==== | + | |
| - | ** 2024-03-12 ** | + | |
| - | + | ||
| - | __Changes__ | + | |
| - | + | ||
| - | VRM deep links: | + | |
| - | + | ||
| - | Connect to remote products in VictronConnect directly from the VRM devices list by clicking the 'Open in VictronConnect' | + | |
| - | [[https:// | + | |
| - | + | ||
| - | * Fix an issue where, in some situations, VictronConnect incorrectly reports the installation as offline when the user tries to connect via deep links. | + | |
| + | * New layout on mobile | ||
| + | * GX details shown at the top for quick access to VRM and Remote Console | ||
| + | * " | ||
| + | * " | ||
| + | * Add support for the recently added Favorites feature in VRM. | ||
| + | * Improve connection and fetching times | ||
| + | * Make VRM installations listing faster, solving an issue that can make VictronConnect to freeze for a while. | ||
| + | * Fix an error that could make the connection stuck at 40% when loading the products list | ||
| + | * Various robustness improvements | ||
| + | * Order products list by name | ||
| + | * VE.Bus inverter/ | ||
| | | ||
| - | + | Inverter, Multi RS: | |
| - | ==== v6.20beta6 ==== | + | |
| - | ** 2025-03-11 ** | + | |
| - | __Changes__ | + | * Add " |
| + | * Disable the Ground relay when the Grid Code has the 'AC Neutral path externally joined' | ||
| + | * Fixes on data reads when System phase is L2 or L3 | ||
| + | * Fix PV Power on the Widget not being updated in remote connections | ||
| + | * Add " | ||
| + | * Add " | ||
| + | * Add firmware v1.26: | ||
| + | * With solar only | ||
| + | * Postpone partial shading scan if the tracker is limited by voltage or power as there is nothing to gain by scanning. | ||
| + | * MultiRS only | ||
| + | * Add grid code support for Austria | ||
| + | * Remove the feed-in restriction of 5kW when using an external AC PV inverter | ||
| + | * Self consumption from the battery can go to all system loads or only critical loads connected to the ac output if there is an energy meter | ||
| + | * Only raise the grid lost alarm if the ac input type is set to grid | ||
| + | * 3 phase configurations and/or parallel configurations only: | ||
| + | * Fix inverter start-up issue, unit would not start charging if the grid returned when 'not allowed to discharge' | ||
| + | * Also include changes from v1.25 | ||
| + | * Add settings synchronisation; | ||
| + | * Add ' | ||
| + | * Various improvements to make the 3-phase system behave as a single device | ||
| + | * Germany: divide maximum charge power 4.2kW by the number of units if the charge restriction is active (EnWG §14a) | ||
| - | VE.Bus Inverter/ | ||
| - | * Add firmware v555 | ||
| - | * Improve system stability for Charge and PowerAssist in combination with certain gensets. On all tested gensets, the system now works stable without the need to enable the Weak AC Input setting. (This improvement is available when the selected gridcode is “None” or “Other”) | ||
| - | * Added support for the German 14a EnWG requirement. Battery charging of the system is limited to 4.2kW when the AUX2 input of the L1 phase master is “closed”. | ||
| - | | ||
| - | ==== v6.20beta5 ==== | + | Energy Meter VM-3P75CT |
| - | ** 2025-02-25 ** | + | |
| - | __Changes__ | + | * Add firmware 1.10 |
| + | * Add power factor live data | ||
| + | * Add phase sequence live data | ||
| + | * Add phase rotation alarm | ||
| + | * Add EV charger and Heatpump roles | ||
| + | * Various improvements | ||
| + | MPPT Solar Chargers: | ||
| - | Lynx Smat BMS NG: | + | |
| - | | + | * Remove |
| - | * Various stability improvements, | + | * Fix some models |
| - | * Improved Lithium-NG | + | |
| - | * Fixed invalid value in maximum cell temperature history (NG models | + | |
| - | * Fixed issue with Cumulative Ah counter. | + | |
| - | * Fixed issue where Lynx Distributors on the system side could incorrectly raise “blown fuse” warnings while the contactor was open. | + | |
| - | * Includes Lithium-NG battery firmware v1.01 | + | |
| - | Lynx Shunt VE.Can : | + | EVCS |
| - | * Add battery voltage calibration | + | |
| - | Multi RS: | + | * Add firmware v2.03 |
| - | * Include grid code settings when exporting & importing settings files | + | * Reduced the voltage drop threshold for detecting a connected EV during the CP auto-calibration procedure |
| - | * Include grid code settings | + | * Fixed an issue with 2s delay before power off in disconnected state |
| - | * Add support | + | * Fixed an issue in the CP auto-calibration procedure that caused calibration to occur in a disconnected state |
| + | | ||
| + | * Add control on the password length | ||
| + | * Fix color manual input selection for lightring settings | ||
| - | VE.Bus | + | Lynx Smart BMS & NG: |
| - | * Various improvements | + | * Added cell-id for min/max voltage/ |
| + | * Add firmware 1.14 | ||
| + | * Improved State of Charge accuracy | ||
| + | * Updated float voltage levels | ||
| + | * Smoother transition to float stage (reduces discharge spikes in ESS systems that feed back into the grid) | ||
| + | * New default Charged Voltage | ||
| + | * NG: Synchronization between battery monitor and charge control added to avoid entering the float stage before battery monitor synchronization is complete | ||
| + | * NG: Fixed the repeated absorption timer broken per v1.08 | ||
| + | * NG: The cell voltage threshold for not-allowed-to-charge contact has been reduced from 3.75V to 3.65V | ||
| + | * NG: Added cell-ID information for minimum and maximum cell voltages and temperatures | ||
| + | * NG: Added a data loop test to validate the communication interface with the batteries (no special handling in VictronConnect App or similar is required) | ||
| + | * NG: Fixed issue with ATC and ATD not being retained when the BMS cable was disconnected | ||
| + | * NG: Fix occasional issue where, especially systems with many batteries, would not start up and raise Error. #2, No battery found | ||
| + | * Fixed alarm relay that was not activating for high temperature alarms | ||
| - | MPPT Solar Chargers: | + | Smart & Blue Smart Chargers |
| - | * Add firmware v1.66 for Smart and BlueSolars 75/10 and 75/15 (from serial number HQ2231 and newer): | + | |
| - | * Fix issue with TX alternate pin feature where, when not selected as " | + | |
| - | * Fix issue with RX alternate pin feature where the functions wouldn' | + | |
| - | ==== v6.20beta4 ==== | + | * Add firmware v3.65 |
| - | ** 2025-02-07 | + | * Add button lock feature to all chargers with a button |
| + | | ||
| + | | ||
| + | | ||
| + | * Impulse-II rev2 hardware models | ||
| + | * Blue Smart Chargers IP22, IP65 and IP67 models, produced after a hardware change made in production near the end of 2019. | ||
| - | __Changes__ | + | VE.Bus inverter/ |
| - | + | * Fix Instant Readout AC out power does not show the sum of all the phases | |
| - | * Fix loading cloud icon is shown intermitently after initial loading | + | |
| - | * Fixed an issue where VictronConnect could sometimes trigger macOS to ask for download new fonts | + | |
| - | * Android: Fixed a flickering issue after the splash screen. | + | |
| - | * Fixed an issue where the splash screen on Android and iOS could appear stretched when opening VictronConnect in landscape orientation | + | |
| - | * Fixed random crashes when a VM-3P75CT is available on the local network | + | |
| - | * Improve responsiveness | + | |
| - | * Fixed duplicate "My devices" | + | |
| - | * Internal improvements to prevent false crash reports when closing VictronConnect | + | |
| - | + | ||
| - | Lynx SmartBMS NG: | + | |
| - | * New settings: (requires a firmware update that has not been released yet) | + | |
| - | * Add 36V battery option | + | |
| - | * Add current measurement direction setting | + | |
| - | * Add " | + | |
| - | + | ||
| - | Smart Chargers: | + | |
| - | * Add support for a new IP43 model | + | |
| VE.Bus BMS NG: | VE.Bus BMS NG: | ||
| - | * Add initial support | ||
| - | Smart Battery Sense: | + | |
| - | | + | |
| - | * Reduced power consumption compared to firmware v1.14 | + | |
| - | ==== v6.20beta3 ==== | + | SolarSense |
| - | ** 2025-01-08 ** | + | |
| - | __Changes__ | + | * Installation peak power is set in Wp instead of kWp to be more precise |
| + | * Better description of the " | ||
| + | * Add data selection for historical values | ||
| + | * Add total estimated energy yield in a period | ||
| + | * Add graphics for historical values | ||
| + | * Add Long History support & show historical maximums | ||
| + | * Add Instant Readout on remote connections | ||
| + | * Fix Instant Readout total yield | ||
| + | * Fix “Installation peak power” behaviour when set values over 655kWp | ||
| - | Orion XS: | + | Demos |
| - | * Add firmware v1.08 | + | * VE.Bus Inverters |
| - | * Fix issue introduced on v1.07 that could lead to the charger failing when the battery voltage is above the output voltage target. | + | * Inform |
| - | + | ||
| - | Smart BatteryProtect: | + | |
| - | * Add firmware v2.12: | + | |
| - | * Released for 12/24V-100A and 12/24V-220A only | + | |
| - | * Fix an issue where a voltage drop to 9V causes misbehavior, | + | |
| - | + | ||
| - | ==== v6.20beta2 ==== | + | |
| - | ** 2024-12-20 ** | + | |
| - | + | ||
| - | __Changes__ | + | |
| - | + | ||
| - | * Add Czech, Korean and Vietnamese translations | + | |
| - | * Add support for various upcoming new products | + | |
| - | * Fix an issue where the Trends page does not save the selected trends under certain circumstances | + | |
| - | + | ||
| - | Solar Chargers: | + | |
| - | * Fix " | + | |
| - | + | ||
| - | Multi RS: | + | |
| - | * Enable setting the grid code for the first time without requiring a password | + | |
| - | * Add "PV Inverter" | + | |
| - | * Improve NS Log handling | + | |
| - | * Fix NS log displaying incorrect time in DST time zones | + | |
| - | * Make possible to hide unused MPPT trackers (requires | + | |
| - | + | ||
| - | MPPT RS: | + | |
| - | * Add an option to hide unused MPPT trackers (requires beta firmware) | + | |
| - | + | ||
| - | Orion XS: | + | |
| - | * Add firmware v1.07 | + | |
| - | * Remote H/L now also included as a condition to pause the charge algorithm as done with low input voltage. Charge algorithm is now paused for a maximum of 2h before triggering a new charge cycle, as already done for low input voltage. If charging resumes before the 2h timeout expires, the charge algorithm is resumed from the state it was previously. | + | |
| - | * Improve overall robustness of the hardware control and internal software to increase reliability even further. | + | |
| - | + | ||
| - | Lynx SmartBMS NG: | + | |
| - | * Make the battery capacity setting non-editable since the value is received from the batteries | + | |
| - | + | ||
| - | + | ||
| - | ==== v6.20beta1 ==== | + | |
| - | ** 2024-11-23 ** | + | |
| - | + | ||
| - | __Changes__ | + | |
| - | + | ||
| - | + | ||
| - | ** New Feature: Support for Deep Links ** | + | |
| - | + | ||
| - | You can now open products in VictronConnect directly from VRM by clicking the "Open in VictronConnect" | + | |
| - | * This feature is not yet available in VRM but will be published soon. | + | |
| - | * Currently supported only on Windows, macOS, and Linux. Support for Android and iOS will be added in a future beta release. | + | |
| - | + | ||
| - | Orion XS: | + | |
| - | * Add firmware v1.06 | + | |
| - | * Fix handling of newer serial numbers that could cause conflicts with VE.Smart networking | + | |
| - | + | ||
| - | EVCS: | + | |
| - | * Fixed an issue where firmware update notifications continued to appear even after completing the update. | + | |
| - | * Notify users when the EVCS is not reachable on the network before attempting a firmware update from the settings menu | + | |
| ==== v6.19 (Released officially) ==== | ==== v6.19 (Released officially) ==== | ||
victronconnect/beta.1752873736.txt.gz · Last modified: by jperez