venus-os:mfd-raymarine
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
venus-os:mfd-raymarine [2021-12-09 09:49] – [7. NMEA 2000] mvader | venus-os:mfd-raymarine [2023-03-01 16:42] – [6. Step by Step] mbosma | ||
---|---|---|---|
Line 34: | Line 34: | ||
:!: It is not possible to use a [[https:// | :!: It is not possible to use a [[https:// | ||
+ | |||
+ | **Note: As of Raymarine LightHouse v3.15, there is an option to toggle DHCP. Disabling this option does not mean that the Axiom MFD will work with third party network routers. See [[https:// | ||
===== 4. Configuration ===== | ===== 4. Configuration ===== | ||
On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)// | On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)// | ||
Line 62: | Line 64: | ||
{{youtube> | {{youtube> | ||
- | After connecting the Ethernet cable the GX device receives an IP number | + | After connecting the Ethernet cable the GX device receives an IP number from the Axiom DHCP. |
If you start the Victron App on the Axiom and it shows " | If you start the Victron App on the Axiom and it shows " | ||
===== 7. NMEA 2000 ===== | ===== 7. NMEA 2000 ===== | ||
Line 87: | Line 89: | ||
=== Raymarine only: data instances need to made unique === | === Raymarine only: data instances need to made unique === | ||
- | If there are more than 1 (for example) SmartShunts in the NMEA2000 network, or a Solar Charger and a SmartShunt, then the Data instances of the Victron | + | If there are more than 1 (for example) SmartShunts in the NMEA2000 network, or a Solar Charger and a SmartShunt, or any other device that transmits the same type of PGNs, then the Data instances of those PGNs need to changed to make each data instance unique. |
+ | |||
+ | Typically this concerns the Battery instance, used in the Battery Status and DC Detailed PGNs. | ||
See here for how to do that: [[https:// | See here for how to do that: [[https:// | ||
**Note**: this requirement of data instances being globally unique for a PGN is specific to Raymarine. Other brands do not require this. And, although perhaps besides the point, also the NMEA2000 standard does not require it. More specifically, | **Note**: this requirement of data instances being globally unique for a PGN is specific to Raymarine. Other brands do not require this. And, although perhaps besides the point, also the NMEA2000 standard does not require it. More specifically, |
venus-os/mfd-raymarine.txt · Last modified: 2023-06-22 19:32 by sloges