+ | **Note: As of Raymarine LightHouse v3.15, there is an option to toggle DHCP. Disabling this option does not mean that the Axiom MFD will work with third party network routers. See [[https:// | ||
===== 4. Configuration ===== | ===== 4. Configuration ===== | ||
On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)// | On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)// | ||
{{: | {{: | ||
- | Next, go to //Settings | + | |
+ | Next, go to Menu -> Settings | ||
{{: | {{: | ||
Line 61: | Line 64: | ||
{{youtube> | {{youtube> | ||
- | After connecting the Ethernet cable the GX device receives an IP number | + | After connecting the Ethernet cable the GX device receives an IP number from the Axiom DHCP. |
If you start the Victron App on the Axiom and it shows " | If you start the Victron App on the Axiom and it shows " | ||
===== 7. NMEA 2000 ===== | ===== 7. NMEA 2000 ===== | ||
- | A Raymarine MFD can also be connected to the Victron system using NMEA 2000. If you’re new to NMEA2000 & Victron, start with reading the [[ve.can: | + | Besides connecting over ethernet, a Raymarine MFD can also be connected to the Victron system using NMEA 2000. If you’re new to NMEA2000 & Victron, start with reading the [[ve.can: |
This chapter explains the specifics of NMEA2000 when connecting Victron to a Raymarine MFD. | This chapter explains the specifics of NMEA2000 when connecting Victron to a Raymarine MFD. | ||
- | If there are more than 1 (for example) SmartShunt in the NMEA2000 network then you change the Data instances of the Victron | + | === 7.1. Generic and supported |
To setup the data sources on the Raymarine, go to //Settings > Network > Sources > Advanced...// | To setup the data sources on the Raymarine, go to //Settings > Network > Sources > Advanced...// | ||
If you have more than 1 battery be sure to adjust the settings of the Axiom to the correct amount of battery(banks). | If you have more than 1 battery be sure to adjust the settings of the Axiom to the correct amount of battery(banks). | ||
- | The following Victron related PGNs are supported: | + | The following Victron related PGNs are supported |
* 127505 - Fluid level (tank levels) | * 127505 - Fluid level (tank levels) | ||
* 127506 - DC Detailed Status (State-of-charge, | * 127506 - DC Detailed Status (State-of-charge, | ||
+ | * 127507 - Charger status | ||
* 127508 - Battery Status (Battery Voltage, Battery Current) | * 127508 - Battery Status (Battery Voltage, Battery Current) | ||
+ | * 127509 - Inverter status | ||
- | When the NMEA2000/ | + | This PGN is not supported by Raymarine: |
- | + | ||
- | Below list of Victron related PGNs are not supported by the Raymarine, ie. in our tests we could not get such data to show on the MFD using NMEA2000 (use the Marine MFD App instead to see the same data!): | + | |
* J1939 - AC data | * J1939 - AC data | ||
+ | |||
+ | When the NMEA2000/ | ||
+ | |||
+ | === 7.2. Instancing requirements when using Raymarine === | ||
+ | |||
+ | Fluid instancing details: | ||
+ | |||
+ | * Raymarine i70: max number of tank levels is 5; fluid instance 0-4 and type must be fuel. | ||
+ | * Raymarine i70s: max number of tank levels is 5; fluid instance 0-4 and type must be fuel. | ||
+ | * Axiom MFDs: per Lighthouse version 4.1.75, a maximum of 16 tanks can be connected; fluid instance 0-15. | ||
+ | |||
+ | ==== LightHouse 4.1.75 and newer versions ==== | ||
+ | As of LightHouse version 4.1.75, the battery instances no longer need to be unique. This means that you can leave the battery instance to its default value, which is typically set to 0. The batteries are automatically detected by the Axiom display. | ||
+ | |||
+ | ==== LightHouse 4.1.74 and prior versions ==== | ||
+ | If there are more than 1 (for example) SmartShunts in the NMEA2000 network, or a Solar Charger and a SmartShunt, or any other device that transmits the same type of PGNs, then the Data instances of those PGNs need to changed to make each data instance unique. | ||
+ | |||
+ | Typically this concerns the Battery instance, used in the Battery Status and DC Detailed PGNs. | ||
+ | |||
+ | See here for how to do that: [[https:// |