venus-os:mfd-raymarine
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
venus-os:mfd-raymarine [2021-04-02 06:58] – [7. NMEA 2000] mvader | venus-os:mfd-raymarine [2021-05-16 21:51] – [3. Wiring] mvader | ||
---|---|---|---|
Line 31: | Line 31: | ||
To connect the [[https:// | To connect the [[https:// | ||
- | :!: Connecting a Axiom MFD to a network router over Ethernet leads to IP address conflicts, due to the integrated DHCP server. | + | :!: Connecting a Axiom MFD to a network router over Ethernet leads to IP address conflicts, due to the integrated DHCP server |
- | :!: It is not possible to use a [[https:// | + | :!: It is not possible to use a [[https:// |
===== 4. Configuration ===== | ===== 4. Configuration ===== | ||
On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)// | On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)// | ||
Line 79: | Line 79: | ||
* 127506 - DC Detailed Status (State-of-charge, | * 127506 - DC Detailed Status (State-of-charge, | ||
* 127508 - Battery Status (Battery Voltage, Battery Current) | * 127508 - Battery Status (Battery Voltage, Battery Current) | ||
+ | |||
+ | When the NMEA2000/ | ||
Below list of Victron related PGNs are not supported by the Raymarine, ie. in our tests we could not get such data to show on the MFD using NMEA2000 (use the Marine MFD App instead to see the same data!): | Below list of Victron related PGNs are not supported by the Raymarine, ie. in our tests we could not get such data to show on the MFD using NMEA2000 (use the Marine MFD App instead to see the same data!): | ||
* J1939 - AC data | * J1939 - AC data |
venus-os/mfd-raymarine.txt · Last modified: 2023-06-22 19:32 by sloges