User Tools

Site Tools


venus-os:mfd-raymarine

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revisionBoth sides next revision
venus-os:mfd-raymarine [2020-06-25 17:34] mbosmavenus-os:mfd-raymarine [2020-06-27 08:07] – [1. Introduction] mvader
Line 8: Line 8:
 Make sure to also study the [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_app|Marine MFD Integration by App chapter in the manual]]. Make sure to also study the [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_app|Marine MFD Integration by App chapter in the manual]].
  
-Note that there is an alternative method to connect, which is NMEA2000. See the [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]].+Note that there is an alternative method to connect, which is NMEA2000. See the [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]], as well as the last chapter in this manual.
 ===== 2. Compatibility ===== ===== 2. Compatibility =====
  
Line 62: Line 62:
 The MFD can also be connected to the GX device using NMEA 2000, see [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]]. The MFD can also be connected to the GX device using NMEA 2000, see [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]].
  
-In order to properly display the NMEA 2000 data from Victron equipment, you need to change the data instances of the PGNs that are sent out. See [[https://www.victronenergy.com/live/ve.can:changing_nmea2000_instances|here]] for more information about changing instances.\\ +In order to properly display the NMEA 2000 data from Victron equipment, you need to change the data instances of the PGNs that are sent out. See here for how to do that: [[https://www.victronenergy.com/live/ve.can:changing_nmea2000_instances|Changing NMEA2000 Instances]], section Data instances. 
-To setup the data sources on the MFD, go to //Settings > Network > Sources > Advanced...//+ 
 +To setup the data sources on the Raymarine, go to //Settings > Network > Sources > Advanced...//
  
 The following Victron related PGNs are supported: The following Victron related PGNs are supported:
-  * 127505 - Fluid level (tanks+  * 127505 - Fluid level (tank levels
-  * 127506 - DC Detailed StatusState-of-charge, Time-to-go +  * 127506 - DC Detailed Status (State-of-charge, Time-to-go) 
-  * 127508 - Battery Status+  * 127508 - Battery Status (Battery Voltage, Battery Current) 
 + 
 +These Victron related PGNs are not supported by the Raymarine, ie. in our tests we could not get such data to show on the MFD using NMEA2000 (use the Marine MFD App instead!): 
 +  * J1939 - AC data
venus-os/mfd-raymarine.txt · Last modified: 2023-06-22 19:32 by sloges

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki