Line 8: Line 8:
 Make sure to also study the [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_app|Marine MFD Integration by App chapter in the manual]]. Make sure to also study the [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_app|Marine MFD Integration by App chapter in the manual]].
  
-Note that there is an alternative method to connect, which is NMEA2000. See the [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]].+Note that there is an alternative method to connect, which is NMEA2000. See the [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]], as well as the last chapter in this manual.
 ===== 2. Compatibility ===== ===== 2. Compatibility =====
  
Line 14: Line 14:
  
 Raymarine MFDs need at least LightHouse v3.11 for compatibility, which was released in November 2019. Raymarine MFDs need at least LightHouse v3.11 for compatibility, which was released in November 2019.
 +
 +From Victron side, all GX devices (Cerbo GX, CCGX, Venus GX, and so forth) can be used and are compatible. For details on detailed product compatibility with regarding to inverter/chargers and other components, see the [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_app|main Marine MFD App chapter in the GX Manual]].
  
 ===== 3. Wiring ===== ===== 3. Wiring =====
Line 58: Line 60:
 {{youtube>dAfJy5d_vcA?large}} {{youtube>dAfJy5d_vcA?large}}
  
 +===== 7. NMEA 2000 =====
 +
 +The MFD can also be connected to the GX device using NMEA 2000, see [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]].
 +
 +In order to properly display the NMEA 2000 data from Victron equipment, you need to change the data instances of the PGNs that are sent out. See here for how to do that: [[https://www.victronenergy.com/live/ve.can:changing_nmea2000_instances|Changing NMEA2000 Instances]], section Data instances.
 +
 +To setup the data sources on the Raymarine, go to //Settings > Network > Sources > Advanced...//
 +
 +The following Victron related PGNs are supported:
 +  * 127505 - Fluid level (tank levels)
 +  * 127506 - DC Detailed Status (State-of-charge, Time-to-go)
 +  * 127508 - Battery Status (Battery Voltage, Battery Current)
 +
 +These Victron related PGNs are not supported by the Raymarine, ie. in our tests we could not get such data to show on the MFD using NMEA2000 (use the Marine MFD App instead!):
 +  * J1939 - AC data