venus-os:mfd-raymarine
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
venus-os:mfd-raymarine [2020-06-11 17:30] – [4. Configuration] mbosma | venus-os:mfd-raymarine [2020-06-25 17:34] – mbosma | ||
---|---|---|---|
Line 26: | Line 26: | ||
* A80513 - RayNet male to RJ45 adaptor cable | * A80513 - RayNet male to RJ45 adaptor cable | ||
- | Connecting a Axiom MFD to a network router lead ls to IP address conflicts, due to the integrated DHCP server. | + | To connect the [[https:// |
- | To connect | + | :!: Connecting a Axiom MFD to a network router over Ethernet leads to IP address conflicts, due to the integrated DHCP server. |
+ | |||
+ | :!: It is not possible to use a [[https:// | ||
===== 4. Configuration ===== | ===== 4. Configuration ===== | ||
On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)// | On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)// | ||
Line 56: | Line 58: | ||
{{youtube> | {{youtube> | ||
+ | ===== 7. NMEA 2000 ===== | ||
+ | |||
+ | The MFD can also be connected to the GX device using NMEA 2000, see [[https:// | ||
+ | |||
+ | In order to properly display the NMEA 2000 data from Victron equipment, you need to change the data instances of the PGNs that are sent out. See [[https:// | ||
+ | To setup the data sources on the MFD, go to //Settings > Network > Sources > Advanced...// | ||
+ | |||
+ | The following Victron related PGNs are supported: | ||
+ | * 127505 - Fluid level (tanks) | ||
+ | * 127506 - DC Detailed Status; State-of-charge, | ||
+ | * 127508 - Battery Status |
venus-os/mfd-raymarine.txt · Last modified: 2023-06-22 19:32 by sloges