venus-os:mfd-raymarine [2020-06-11 17:30] – [4. Configuration] mbosmavenus-os:mfd-raymarine [2020-06-25 17:34] mbosma
Line 26: Line 26:
   * A80513 - RayNet male to RJ45 adaptor cable   * A80513 - RayNet male to RJ45 adaptor cable
  
-Connecting a Axiom MFD to a network router lead ls to IP address conflictsdue to the integrated DHCP server+To connect the [[https://www.victronenergy.com/live/venus-os:start|GX device]] to the internet as well, use Wi-Fi. If the Axiom MFD is connected to internet (using Wi-Fi)it will automatically share its connection with the GX device over ethernet.
  
-To connect the [[https://www.victronenergy.com/live/venus-os:start|GX device]] to the internet as well, use WiFi+:!: Connecting a Axiom MFD to a network router over Ethernet leads to IP address conflicts, due to the integrated DHCP server.  
 + 
 +:!: It is not possible to use a [[https://www.victronenergy.com/accessories/gx-gsm|GX GSM]], due to the integrated DHCP server of the Axiom MFD.
 ===== 4. Configuration =====  ===== 4. Configuration ===== 
 On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)//. On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)//.
Line 56: Line 58:
 {{youtube>dAfJy5d_vcA?large}} {{youtube>dAfJy5d_vcA?large}}
  
 +===== 7. NMEA 2000 =====
 +
 +The MFD can also be connected to the GX device using NMEA 2000, see [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]].
 +
 +In order to properly display the NMEA 2000 data from Victron equipment, you need to change the data instances of the PGNs that are sent out. See [[https://www.victronenergy.com/live/ve.can:changing_nmea2000_instances|here]] for more information about changing instances.\\
 +To setup the data sources on the MFD, go to //Settings > Network > Sources > Advanced...//
 +
 +The following Victron related PGNs are supported:
 +  * 127505 - Fluid level (tanks)
 +  * 127506 - DC Detailed Status; State-of-charge, Time-to-go
 +  * 127508 - Battery Status