venus-os:mfd-raymarine
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
venus-os:mfd-raymarine [2020-02-25 08:45] – [4. Configuration] mbosma | venus-os:mfd-raymarine [2020-05-01 11:10] – [1. Introduction] mvader | ||
---|---|---|---|
Line 3: | Line 3: | ||
===== 1. Introduction ===== | ===== 1. Introduction ===== | ||
- | The integration technology used is called [[http:// | + | This document explains how to connect to Raymarine MFDs using an Ethernet connection. |
+ | The integration technology used is called [[http:// | ||
+ | Make sure to also study the [[https:// | ||
+ | |||
+ | Note that there is an alternative method to connect, which is NMEA2000. See the [[https:// | ||
===== 2. Compatibility ===== | ===== 2. Compatibility ===== | ||
Line 22: | Line 26: | ||
* A80513 - RayNet male to RJ45 adaptor cable | * A80513 - RayNet male to RJ45 adaptor cable | ||
+ | Connecting a Axiom MFD to a network router lead ls to IP address conflicts, due to the integrated DHCP server. | ||
+ | |||
+ | To connect the [[https:// | ||
===== 4. Configuration ===== | ===== 4. Configuration ===== | ||
On the Victron GX Device, go to Settings → Services, and there enable both MQTT on LAN (SSL) and MQTT on LAN (Plaintext). | On the Victron GX Device, go to Settings → Services, and there enable both MQTT on LAN (SSL) and MQTT on LAN (Plaintext). | ||
Line 28: | Line 35: | ||
No other settings, such as IP addresses or similar are required, since the Axiom MFDs have an integrated DHCP server. | No other settings, such as IP addresses or similar are required, since the Axiom MFDs have an integrated DHCP server. | ||
- | |||
===== 5. Configuring Multiple Battery Measurements ===== | ===== 5. Configuring Multiple Battery Measurements ===== | ||
venus-os/mfd-raymarine.txt · Last modified: 2023-06-22 19:32 by sloges