venus-os:mfd-raymarine [2023-03-01 16:42] – [6. Step by Step] mbosmavenus-os:mfd-raymarine [2023-03-02 09:19] – [7. NMEA 2000] mbosma
Line 72: Line 72:
 This chapter explains the specifics of NMEA2000 when connecting Victron to a Raymarine MFD. This chapter explains the specifics of NMEA2000 when connecting Victron to a Raymarine MFD.
  
-=== Generic and supported PGNs ===+=== 7.1. Generic and supported PGNs ===
 To setup the data sources on the Raymarine, go to //Settings > Network > Sources > Advanced...// To setup the data sources on the Raymarine, go to //Settings > Network > Sources > Advanced...//
  
Line 80: Line 80:
   * 127505 - Fluid level (tank levels)   * 127505 - Fluid level (tank levels)
   * 127506 - DC Detailed Status (State-of-charge, Time-to-go)   * 127506 - DC Detailed Status (State-of-charge, Time-to-go)
 +  * 127507 - Charger status
   * 127508 - Battery Status (Battery Voltage, Battery Current)   * 127508 - Battery Status (Battery Voltage, Battery Current)
 +  * 127509 - Inverter status
  
 This PGN is not supported by Raymarine: This PGN is not supported by Raymarine:
Line 87: Line 89:
 When the NMEA2000/STNG network has GPS data the GX device sees this as a GPS source and is able to use the GPS position in VRM. When the NMEA2000/STNG network has GPS data the GX device sees this as a GPS source and is able to use the GPS position in VRM.
  
-=== Raymarine only: data instances need to made unique ===+=== 7.2. LightHouse 4.1.75 and newer === 
 +As of LightHouse version 4.1.75, the battery instances no longer need to be unique. This means that you can leave the battery instance to its default value, which is typically set to 0. The batteries are automatically detected by the Axiom display.
  
 +=== 7.3. Before LightHouse 4.1.75 ===
 If there are more than 1 (for example) SmartShunts in the NMEA2000 network, or a Solar Charger and a SmartShunt, or any other device that transmits the same type of PGNs, then the Data instances of those PGNs need to changed to make each data instance unique. If there are more than 1 (for example) SmartShunts in the NMEA2000 network, or a Solar Charger and a SmartShunt, or any other device that transmits the same type of PGNs, then the Data instances of those PGNs need to changed to make each data instance unique.
  