Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionLast revisionBoth sides next revision | ||
venus-os:mfd-furuno [2020-06-25 15:36] – [6. NMEA 2000] mbosma | venus-os:mfd-furuno [2023-04-13 13:16] – [6. NMEA 2000] mvader | ||
---|---|---|---|
Line 11: | Line 11: | ||
===== 2. Compatibility ===== | ===== 2. Compatibility ===== | ||
- | The MFD integration is compatible with the following | + | The MFD integration is compatible with the following |
* NavNet TZtouch3 TZT12F | * NavNet TZtouch3 TZT12F | ||
* NavNet TZtouch3 TZT16F | * NavNet TZtouch3 TZT16F | ||
* NavNet TZtouch3 TZT19F | * NavNet TZtouch3 TZT19F | ||
* Navnet TZtouch2 TZT2BB Black box | * Navnet TZtouch2 TZT2BB Black box | ||
- | NavNet TZtouch3 MFDs need at least software version v1.08. The Navnet TZtouch2 TZT2BB needs at least software version v7. | + | * NavNet TZtouchXL TZT22X |
+ | * NavNet TZtouchXL TZT24X | ||
+ | |||
+ | NavNet TZtouch3 MFDs need at least software version v1.08. The Navnet TZtouch2 TZT2BB needs at least software version v7.01. | ||
Note that the Navnet TZtouch2 TZT**L** models are **not** supported. | Note that the Navnet TZtouch2 TZT**L** models are **not** supported. | ||
+ | |||
+ | From Victron side, all GX devices (Cerbo GX, CCGX, Venus GX, and so forth) can be used and are compatible. For details on detailed product compatibility with regarding to inverter/ | ||
===== 3. Wiring ===== | ===== 3. Wiring ===== | ||
Line 36: | Line 41: | ||
{{: | {{: | ||
- | It is possible to connect a router to the same LAN; and that way connect the GX Device to the internet. Make sure the //Gateway// and //DNS Server// settings of the GX are set to the IP address of the router. | + | It is possible to connect a router to the same LAN; and that way connect the GX Device to the internet. Make sure the //Gateway// and //DNS Server// settings of the GX are set to the IP address of the router, and that the router has its LAN IP addressing configured in the same subnet. |
+ | :!: It is not possible to use a [[https:// | ||
==== 4.2 Services configuration ==== | ==== 4.2 Services configuration ==== | ||
On the Victron GX Device, go to //Settings -> Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)// | On the Victron GX Device, go to //Settings -> Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)// | ||
{{: | {{: | ||
- | Next, go to //Settings | + | Next, go to Menu → Settings |
{{: | {{: | ||
Line 53: | Line 59: | ||
===== 6. NMEA 2000 ===== | ===== 6. NMEA 2000 ===== | ||
- | The MFD can also be connected to the GX device | + | The MFD can also be connected to the Victron system |
+ | |||
+ | This chapter documents the specifics when displaying Victron NMEA 2000 information on a Furuno MFDs. Note that this is not meant to be an extensive guide. Its the simple result of our R&D checking everything on a Furuno MFD. The functionality is (mostly) dictated by Furuno software and may therefore also change and improve when Furuno company changes their software. | ||
+ | |||
+ | The MFD can be configured easily to display the data from the GX device. To display tank data, there is no need to change any instance. \\ | ||
+ | In order to properly display battery/DC data from Victron equipment, you need to change the data instances of the PGNs that are sent out. See here for how to do that: [[https:// | ||
- | The MFD can be configured easily to display the data from the GX device. There is no need to change any instance. | ||
To view NMEA 2000 devices on the MFD, go to //Settings > Initial Setup > Data Aquisition > Sensor List//. Here you can view basic information and change device instances and custom names. | To view NMEA 2000 devices on the MFD, go to //Settings > Initial Setup > Data Aquisition > Sensor List//. Here you can view basic information and change device instances and custom names. | ||
The following Victron PGNs are supported: | The following Victron PGNs are supported: | ||
* 127505 - Fluid level (tanks) | * 127505 - Fluid level (tanks) | ||
- | * 127506 - DC Detailed Status (limited support); State-of-charge, | + | * 127506 - DC Detailed Status (limited support); State-of-charge, |
- | * 127508 - Battery Status (limited support); Voltage, Current | + | * 127508 - Battery Status (limited support); Voltage, Current |
+ | |||
+ | **Notes** | ||
+ | - The tested Furuno MFD firmware supports a maximum of 4 batteries, no more | ||
+ | - Due to a bug in the MFD firmware, a negative battery current (ie. when discharging) is shown as '' |
venus-os/mfd-furuno.txt · Last modified: 2023-06-22 19:27 by sloges