ve.bus:ve.bus_error_codes
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revision | |||
| ve.bus:ve.bus_error_codes [2024-04-24 00:32] – [Error 26 - Internal error] mleeftink | ve.bus:ve.bus_error_codes [2024-07-03 17:09] (current) – [Error 25 - Incompatible VE.Bus configuration] pba | ||
|---|---|---|---|
| Line 394: | Line 394: | ||
| __Recovery: | __Recovery: | ||
| - | ==== Error 25 - Firmware incompatibility | + | ==== Error 25 - Incompatible VE.Bus configuration |
| - | Make sure to use the same firmware in all devices. | + | The VE.Bus configuration as configured is not allowed. This can be due to the fact that: |
| + | - Devices with different firmware versions are used.\\ Solution: | ||
| + | - Devices are not compatible with this configuration.\\ Check the **compatibility ID**'s which can be found on the stickers of the units.< | ||
| + | * Make sure that the 4-digit number in the compatibility ID of all units in the VE.Bus system is identical . | ||
| + | * Make sure that units in a single phase (so parallel units) have an identical letter in the compatibility ID. | ||
| - | Solution: update all devices to the latest available firmware. Instructions [[updating_firmware: | + | __Recovery__: system remains off until configured correctly and restarted. |
| - | + | ||
| - | __Recovery: | + | |
| + | < | ||
| ==== Error 26 - Internal error ==== | ==== Error 26 - Internal error ==== | ||
| Should not occur. Switch all equipment off, and then on again; it will then resume operation. Contact Victron Energy if the problem persists. | Should not occur. Switch all equipment off, and then on again; it will then resume operation. Contact Victron Energy if the problem persists. | ||
ve.bus/ve.bus_error_codes.1713911572.txt.gz · Last modified: by mleeftink