User Tools

Site Tools


ve.bus:skip-absorption

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Last revisionBoth sides next revision
ve.bus:skip-absorption [2023-07-14 18:28] – [2. Config instructions] mvaderve.bus:skip-absorption [2023-07-20 16:46] jpasop
Line 4: Line 4:
  
 Status in details: Status in details:
-  - VE.Bus Firmware, implement float-only feature - done per version 26/27xx506; which is not available to the public yet+  - VE.Bus Firmware, implement float-only feature - done per version 26/27xx506; which is included in VictronConnect V5.92beta1 
-  - VEConfigure, add float-only config option - pending. Expected late June 2023+  - VEConfigure, add float-only config option - Included in VEConfigure Version 90.04,236(Beta) 
-  - VictronConnect, add float-only setting & add user control to override it in case a full charge from shore is needed - pending+  - VictronConnect, add float-only setting & add user control to override it in case a full charge from shore is needed - Included in VictronConnect V5.92beta1 
-  - Venus OS Normal GUI, add user control to override it in case a full charge from shore is needed.+  - Venus OS Normal GUI, add user control to override it in case a full charge from shore is needed. - Included in Venus OS v3.10~17
   - Venus OS HTML5 GUI, add user control to override it in case a full charge from shore is needed - pending.   - Venus OS HTML5 GUI, add user control to override it in case a full charge from shore is needed - pending.
   - VRM Dashboard controls, same - pending.   - VRM Dashboard controls, same - pending.
Line 35: Line 35:
 Update VE.Bus firmware to 506 or higher: Update VE.Bus firmware to 506 or higher:
  
-  * Install the VictronConnect beta version XXX or later, available [[https://www.victronenergy.com/live/victronconnect:beta|here]], and use that to update the firmware of the Multis or Quattro.+  * Install the VictronConnect beta version V5.92beta1 or later, available [[https://www.victronenergy.com/live/victronconnect:beta#v592beta1|here]], and use that to update the firmware of the Multis or Quattro.
  
  
-For now, VictronConnect beta is the only source for the new 506 firmware, therefor these two normal options are not possible at the moment.+For now, VictronConnect beta is the only source for the new 506 firmware, therefor the firmware update through VRM option is not possible at the moment.
  
-  * <del>To do that locally, using an MK3-USB adapter, use VictronConnect. [[https://www.victronenergy.com/media/pg/VictronConnect_configuration_guide_for_VE.Bus_products/en/firmware-updates.html|Full instructions]].</del>+  * To update locally, using an MK3-USB adapter, use VictronConnect. [[https://www.victronenergy.com/media/pg/VictronConnect_configuration_guide_for_VE.Bus_products/en/firmware-updates.html|Full instructions]].
   * <del>To do that remotely, over the internet, see [[https://www.victronenergy.com/live/venus-os:remote_ve.bus_firmware_updates |the Remote VE.Bus firmware update instructions]].</del>   * <del>To do that remotely, over the internet, see [[https://www.victronenergy.com/live/venus-os:remote_ve.bus_firmware_updates |the Remote VE.Bus firmware update instructions]].</del>
  
 === Step 2 - Enable the mode === === Step 2 - Enable the mode ===
 +== VictronConnect ==
 +The setting is available in VictronConnect in the advanced tab of the settings: 
  
 +{{ :ve.bus:vc_advanced.png?nolink&400 |}}
 +
 +== VeConfigure ==
 The setting is enabled in VEConfigure, on the advanced tab: The setting is enabled in VEConfigure, on the advanced tab:
  
ve.bus/skip-absorption.txt · Last modified: 2023-07-28 17:25 by mvader

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki