| Line 178: | Line 178: | ||
| PV panel isolation resistance too low. | PV panel isolation resistance too low. | ||
| Check the PV array cabling and panel isolation, the inverter restarts automatically once the issue is resolved. | Check the PV array cabling and panel isolation, the inverter restarts automatically once the issue is resolved. | ||
| + | Consider disconnecting the PV array using the PV switch to resume AC operation. | ||
| ==== Err 42 - Inverter shutdown (PV isolation) ==== | ==== Err 42 - Inverter shutdown (PV isolation) ==== | ||
| The ground leakage current in the PV array exceeds the allowed 30mA limit. | The ground leakage current in the PV array exceeds the allowed 30mA limit. | ||
| Check the PV array cabling and panel isolation. | Check the PV array cabling and panel isolation. | ||
| - | Check the installation and restart the unit using the power-switch. | + | Consider disconnecting |
| ==== Err 43 - Inverter shutdown (Ground Fault) ==== | ==== Err 43 - Inverter shutdown (Ground Fault) ==== | ||