 +==== Err 76 - Network incomplete ====
 +Applies to Inverter RS and Multi RS models.
 +
 +The inverters shut down because there are insufficient units to operate a networked setup. Check if all required units are powered on and that the CAN interface cables are connected properly.
 +All units remain off until the installation is fixed, after which the units resume operation.
 +
 +Related configuration settings in VictronConnect are "Prevent CAN network islanding" + "Number of inverters in the system" and "Continue with missing phase" in the System section.
  