mppt-error-codes
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
mppt-error-codes [2020-05-06 10:43] – [Err 68 - Network misconfigured] tabreu | mppt-error-codes [2020-07-12 10:50] – [Err 119 - Settings data lost] mvader | ||
---|---|---|---|
Line 129: | Line 129: | ||
To clear the error on the SmartSolar VE.Direct MPPTs update the FW version to v1.48 or higher. | To clear the error on the SmartSolar VE.Direct MPPTs update the FW version to v1.48 or higher. | ||
- | To clear the error on the SmartSolar/ | + | To clear the error on the SmartSolar/ |
- | Note: Connecting a Solar charger on both VE.Can and VE.Direct is not supported. | + | |
- | The error occur when the charger detects multiple conflicting network sources, with the same priority, trying to send the same information to the charger. VE.Can and VE.Direct interfaces have both the same priority level, and BLE (using VE.Smart Networking) has a lower priority. | + | __Background__ |
+ | |||
+ | Error 68 indicates that the charger detects multiple conflicting network sources, with the same priority, trying to send the same information to the charger. VE.Can and VE.Direct interfaces have both the same priority level, and BLE (using VE.Smart Networking) has a lower priority. | ||
Having a higher priority level means that, if the same information (e.g. Battery voltage sense) is being received from both VE.Can and BLE (using VE.Smart Network) by the charger, the information on VE.Can will be used and the one coming from BLE will be ignored. | Having a higher priority level means that, if the same information (e.g. Battery voltage sense) is being received from both VE.Can and BLE (using VE.Smart Network) by the charger, the information on VE.Can will be used and the one coming from BLE will be ignored. | ||
- | Now, if the same information is being received from two interfaces that has the same priority level (as VE.Can and VE.Direct), the charger does not know how to prioritize those, | + | Now, if the same information is being received from two interfaces that have the same priority level (as VE.Can and VE.Direct), the charger does not know how to prioritize those, |
Line 159: | Line 160: | ||
- Reconfigure the charger. | - Reconfigure the charger. | ||
+ | Please do report this to your Victron dealer and ask him to escalate it to Victron; as this error should never happen. Preferably include firmware version and any other specifics (VRM URL, VictronConnect screenshots or similar). | ||
mppt-error-codes.txt · Last modified: 2024-02-12 05:48 by guy_stewart