User Tools

Site Tools


mppt-error-codes

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revisionBoth sides next revision
mppt-error-codes [2020-01-17 12:09] – external edit 127.0.0.1mppt-error-codes [2020-02-04 10:54] – [Err 68 - Network misconfigured] tabreu
Line 128: Line 128:
 Applies to SmartSolar MPPTs and SmartSolar MPPTs VE.Can. Applies to SmartSolar MPPTs and SmartSolar MPPTs VE.Can.
  
-The typical reason for the error to show is that the charger is configured to operate in parallel using our [[https://www.victronenergy.com/live/victronconnect:ve-smart-networking|wireless VE.Smart protocol]]; and at the same time it is part of an [[https://www.victronenergy.com/live/ess:start|Energy Storage System (ESS)]]. Or its used in an installation with an intelligent battery. In all those cases, the charger is being externally controlled (by ESS and/or intelligent battery), and should therefor not at the same time be configured for parallel operation.+The typical reason for the error to show is that the charger is configured to operate in parallel using our [[https://www.victronenergy.com/live/victronconnect:ve-smart-networking|wireless VE.Smart protocol]]; and at the same time it is part of an [[https://www.victronenergy.com/live/ess:start|Energy Storage System (ESS)]]. Or its used in an installation with an intelligent battery. In all those cases, the charger is being externally controlled (by ESS and/or intelligent battery), and should therefore not at the same time be configured for parallel operation
 + 
 +The error might be intermittent as the charger will always try to reset the fault. There is a 10 seconds delay to retry resetting the error in order for the error to be seen and broadcast to the interfaces
  
 Resolution: disable the parallel operation by connecting VictronConnect, going to settings, then "VE.Smart networking" and choose "Leave network". Resolution: disable the parallel operation by connecting VictronConnect, going to settings, then "VE.Smart networking" and choose "Leave network".
Line 134: Line 136:
 For SmartSolar MPPT VE.Can only, also make sure its not connected to a [[https://www.victronenergy.com/live/venus-os:start|GX Device]] via both VE.Can and VE.Direct. Either disconnect the VE.CAN cable or the VE.Direct cable. For SmartSolar MPPT VE.Can only, also make sure its not connected to a [[https://www.victronenergy.com/live/venus-os:start|GX Device]] via both VE.Can and VE.Direct. Either disconnect the VE.CAN cable or the VE.Direct cable.
  
-Once the conflict is resolved the error will disappear and the charger will resume normal operation, usually within a minute.+Once the conflict is resolved the error will disappear and the charger will resume normal operation, within a minute.
  
  
mppt-error-codes.txt · Last modified: 2024-02-12 05:48 by guy_stewart