mppt-error-codes [2019-05-20 10:55] – [Err 116 - Calibration data lost] rvanzundertmppt-error-codes [2019-07-05 06:43] – [Err 20 - Maximum Bulk-time exceeded] mvader
Line 37: Line 37:
  
 ==== Err 20 - Maximum Bulk-time exceeded ==== ==== Err 20 - Maximum Bulk-time exceeded ====
-This error can only occur when the maximun bulk-time protection is active. 
-This error will not auto-reset. 
-This error is generated when the battery-absorption-voltage is not reached after 10 hours of charging. 
  
-This protection is default disabled in all Solar Chargers.+=== Solar Chargers === 
 +The maximum bulk time protection is a feature that was in the chargers when they were just released (2015 or earlier) and later the feature was removed.
  
-It is default enabled on the Skylla-i and the Skylla IP44.+If you do see this error, then update to the latest firmware.
  
-Our advice is to not enable it on solar chargers.+If you then still have the error, perform a reset to factory defaults of the configuration, and reconfigure the solar charger. 
 + 
 +=== AC Chargers === 
 +This protection is default enabled on the Skylla-i and the Skylla IP44. 
 + 
 +This error is generated when the battery-absorption-voltage is not reached after 10 hours of charging.
  
 +The feature of this safety protection is to detect a shorted cell; and stop charging. 