Line 37: | Line 37: | ||
==== Err 20 - Maximum Bulk-time exceeded ==== | ==== Err 20 - Maximum Bulk-time exceeded ==== | ||
- | This error can only occur when the maximun bulk-time protection is active. | ||
- | This error will not auto-reset. | ||
- | This error is generated when the battery-absorption-voltage is not reached after 10 hours of charging. | ||
- | This protection is default disabled | + | === Solar Chargers === |
+ | The maximum bulk time protection is a feature that was in the chargers when they were just released (2015 or earlier) and later the feature was removed. | ||
- | It is default enabled on the Skylla-i and the Skylla IP44. | + | If you do see this error, then update to the latest firmware. |
- | Our advice is to not enable it on solar chargers. | + | If you then still have the error, perform a reset to factory defaults of the configuration, |
+ | |||
+ | === AC Chargers === | ||
+ | This protection is default enabled on the Skylla-i and the Skylla IP44. | ||
+ | |||
+ | This error is generated when the battery-absorption-voltage is not reached after 10 hours of charging. | ||
+ | The feature of this safety protection is to detect a shorted cell; and stop charging. | ||
==== Err 21 - Current sensor issue ==== | ==== Err 21 - Current sensor issue ==== | ||
Line 110: | Line 114: | ||
Note that (solar-)chargers automatically configure themselves to be BMS-controlled when they are connected to one; either direct or via a Color Control GX or Venus GX. | Note that (solar-)chargers automatically configure themselves to be BMS-controlled when they are connected to one; either direct or via a Color Control GX or Venus GX. | ||
+ | |||
+ | ==== Err 68 - Network misconfigured ==== | ||
+ | |||
+ | The charger detects multiple conflicting network sources trying to take control of the charger. | ||
+ | |||
+ | Applies to SmartSolar MPPTs and SmartSolar MPPTs VE.Can. | ||
+ | |||
+ | The typical reason for the error to show is that the charger is configured to operate in parallel using our [[https:// | ||
+ | |||
+ | Resolution: disable the parallel operation by connecting VictronConnect, | ||
+ | |||
+ | For SmartSolar MPPT VE.Can only, also make sure its not connected to a [[https:// | ||
+ | |||
+ | Once the conflict is resolved the error will disappear and the charger will resume normal operation, usually within a minute. | ||
+ | |||
+ | |||
==== Err 114 - CPU temperature too high ==== | ==== Err 114 - CPU temperature too high ==== | ||
Line 121: | Line 141: | ||
If the error is only present in the history data and the unit operates normally this error can be ignored safely. Explanation: | If the error is only present in the history data and the unit operates normally this error can be ignored safely. Explanation: | ||
+ | SmartSolar models (not the BlueSolar models): upgrading to v1.4x firmware is a one-way trip, you cannot go back to an older firmware version once you upgrade to v1.4x. Reverting to older firmware gives error 116 (calibration data lost), this can be fixed by re-installing the v1.4x firmware. | ||
==== Err 119 - Settings data lost ==== | ==== Err 119 - Settings data lost ==== | ||
The charger cannot read its configuration, | The charger cannot read its configuration, | ||