Note that (solar-)chargers automatically configure themselves to be BMS-controlled when they are connected to one; either direct or via a Color Control GX or Venus GX. | Note that (solar-)chargers automatically configure themselves to be BMS-controlled when they are connected to one; either direct or via a Color Control GX or Venus GX. | ||
+ | |||
+ | ==== Err 68 - Network misconfigured ==== | ||
+ | |||
+ | The charger detects multiple conflicting network sources trying to take control of the charger. | ||
+ | |||
+ | All Smart Solar charger models: | ||
+ | |||
+ | * If the charger is connected to a Venus GX device that takes control of the charger (by sending Charge Voltage Limits to the unit), the charger cannot not be joined to a VE.Smart network as well. In VictronConnect go to settings " | ||
+ | |||
+ | VE.CAN Smart Solar chargers only: | ||
+ | |||
+ | * If the charger is connected via VE.CAN to a Venus GX device do not install a VE.Direct cable to a Venus GX device as well. Either disconnect the VE.CAN cable or the VE.Direct cable. | ||
+ | |||
+ | Once the conflict is resolved the error will disappear and the charger will resume normal operation, usually within a minute. | ||
+ | |||
+ | |||
==== Err 114 - CPU temperature too high ==== | ==== Err 114 - CPU temperature too high ==== | ||
Line 130: | Line 146: | ||
- wait 3 minutes, and power up again. | - wait 3 minutes, and power up again. | ||
- Reconfigure the charger. | - Reconfigure the charger. | ||
+ | |||
===== DISQUS ===== | ===== DISQUS ===== | ||
~~DISQUS~~ | ~~DISQUS~~ | ||
+ |
mppt-error-codes.txt · Last modified: 2024-02-12 05:48 by guy_stewart