Next revisionBoth sides next revision
mppt-error-codes [2018-05-09 10:27] – [Err 116 - Calibration data lost] rvanzundertmppt-error-codes [2019-01-21 11:20] – [DISQUS] ictbeheer
Line 33: Line 33:
 ==== Err 18 - Controller over-current ==== ==== Err 18 - Controller over-current ====
 This error will auto-reset. This error will auto-reset.
-Disconnect the charge controller from all power-sources, wait 3 minutes, and power up again. +If the error does not auto-reset disconnect the charge controller from all power-sources, wait 3 minutes, and power up again. If the error persists the charge controller is probably faulty
-If the error persists the charge controller is probably faulty.+A cause for this error can be switching on a very large load on the battery side.
  
 ==== Err 20 - Maximum Bulk-time exceeded ==== ==== Err 20 - Maximum Bulk-time exceeded ====
Line 58: Line 58:
  
 This error will auto-reset. This error will auto-reset.
 +
 +==== Err 28 - Power stage issue ====
 +
 +This error will not auto-reset.
 +
 +Disconnect all wires, and then reconnect all wires. If the error persists the charge controller is probably faulty.
  
 ==== Err 33 - PV over-voltage ==== ==== Err 33 - PV over-voltage ====
Line 126: Line 132:
  
  
-===== DISQUS ===== +
-~~DISQUS~~+