Line 33: | Line 33: | ||
==== Err 18 - Controller over-current ==== | ==== Err 18 - Controller over-current ==== | ||
This error will auto-reset. | This error will auto-reset. | ||
- | Disconnect | + | If the error does not auto-reset disconnect |
- | If the error persists the charge controller is probably faulty. | + | A cause for this error can be switching on a very large load on the battery side. |
==== Err 20 - Maximum Bulk-time exceeded ==== | ==== Err 20 - Maximum Bulk-time exceeded ==== | ||
Line 58: | Line 58: | ||
This error will auto-reset. | This error will auto-reset. | ||
+ | |||
+ | ==== Err 28 - Power stage issue ==== | ||
+ | |||
+ | This error will not auto-reset. | ||
+ | |||
+ | Disconnect all wires, and then reconnect all wires. If the error persists the charge controller is probably faulty. | ||
==== Err 33 - PV over-voltage ==== | ==== Err 33 - PV over-voltage ==== | ||
Line 65: | Line 71: | ||
==== Err 34 - PV over-current ==== | ==== Err 34 - PV over-current ==== | ||
The current from the solar-panel array has exceeded 75A. This error could be generated due to an internal system fault. | The current from the solar-panel array has exceeded 75A. This error could be generated due to an internal system fault. | ||
- | Disconnect the charger from all power-sources, | + | Disconnect the charger from all power-sources, |
- | This error will auto-reset. | + | |
- | ==== Err 38 - Input shutdown | + | ==== Err 38, Err 39 - PV Input shutdown ==== |
- | To protect the battery from over-charging the panel input is shut down. To recover from this condition first disconnect the solar panels and disconnect the battery. Wait for 3 minutes reconnect the battery first and next the panels. | + | To protect the battery from over-charging the panel input is shorted. |
- | A common reason | + | Possible reasons |
+ | * The Battery voltage (12/24/48V) is set, or auto-detected, | ||
+ | * There is another device connected to the battery, which is configured to a higher voltage. For example a MultiPlus, configured to equalise at 17 Volts, while in the MPPT this is not configured. | ||
+ | * The battery is disconnected using a manual switch. Ideally the charger should be switched off before disconnecting the battery, this avoids a voltage overshoot on the charger output. If necessary the voltage trip-level for the PV Short protection can be increased by raising the Equalization voltage set-point (note: equalization does not have to be enabled in this case). | ||
+ | * The battery is disconnected using a Lithium charge relay connected to the “allow-to-charge” output of a BMS. Consider wiring this signal to the Remote terminal of the charger instead. This shuts down the charger gracefully without creating a voltage overshoot. | ||
- | Use VictronConnect to disable auto-detect | + | Error recovery: |
+ | * Error 38: First disconnect the solar panels | ||
+ | * Error 39: The charger will automatically resume operation once the battery | ||
If the error persists the charge controller is probably faulty. | If the error persists the charge controller is probably faulty. | ||
+ | |||
==== Information 65 - Communication warning ==== | ==== Information 65 - Communication warning ==== | ||
Communication with one of the paralleled controllers was lost. To clear the warning, switch the controller off and back on | Communication with one of the paralleled controllers was lost. To clear the warning, switch the controller off and back on | ||
Line 99: | Line 111: | ||
Note that (solar-)chargers automatically configure themselves to be BMS-controlled when they are connected to one; either direct or via a Color Control GX or Venus GX. | Note that (solar-)chargers automatically configure themselves to be BMS-controlled when they are connected to one; either direct or via a Color Control GX or Venus GX. | ||
- | ==== Err 114 - CPU temperature | + | ==== Err 68 - Network misconfigured ==== |
+ | |||
+ | The charger detects multiple conflicting network sources trying to take control of the charger. | ||
+ | |||
+ | Applies to SmartSolar MPPTs and SmartSolar MPPTs VE.Can. | ||
+ | |||
+ | The typical reason for the error to show is that the charger is configured to operate in parallel using our [[https:// | ||
+ | |||
+ | Resolution: disable the parallel operation by connecting VictronConnect, | ||
+ | |||
+ | For SmartSolar MPPT VE.Can only, also make sure its not connected to a [[https:// | ||
+ | |||
+ | Once the conflict is resolved the error will disappear and the charger will resume normal operation, usually within a minute. | ||
+ | |||
+ | |||
+ | |||
+ | ==== Err 114 - CPU temperature | ||
This error will reset after the CPU has cooled down. | This error will reset after the CPU has cooled down. | ||
If the error persists, check the ambient temperature and check for obstructions near the air inlet and outlet holes of the charger cabinet. | If the error persists, check the ambient temperature and check for obstructions near the air inlet and outlet holes of the charger cabinet. | ||
Line 105: | Line 133: | ||
==== Err 116 - Calibration data lost ==== | ==== Err 116 - Calibration data lost ==== | ||
- | The unit is faulty, contact your dealer for a replacement. | + | If the unit does not work and error 116 pops up as the active error the unit is faulty, contact your dealer for a replacement. |
+ | |||
+ | If the error is only present in the history data and the unit operates normally this error can be ignored safely. Explanation: | ||
==== Err 119 - Settings data lost ==== | ==== Err 119 - Settings data lost ==== | ||
Line 115: | Line 146: | ||
- wait 3 minutes, and power up again. | - wait 3 minutes, and power up again. | ||
- Reconfigure the charger. | - Reconfigure the charger. | ||
+ | |||