mppt-error-codes
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
mppt-error-codes [2017-02-05 22:13] – [Err 67 - No BMS] mvader | mppt-error-codes [2019-05-20 10:55] – [Err 116 - Calibration data lost] rvanzundert | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== MPPT Solar Charger Error Codes ====== | ====== MPPT Solar Charger Error Codes ====== | ||
+ | Solar Chargers indicate an error with their LEDs. See the [[https:// | ||
+ | |||
+ | Detailed error codes can be read with a remote panel, such as the Color Control GX or the MPPT Control. | ||
===== Error Codes ===== | ===== Error Codes ===== | ||
Line 7: | Line 10: | ||
This error will auto-reset after the battery voltage has dropped. | This error will auto-reset after the battery voltage has dropped. | ||
This error can be due to other charging equipment connected to the battery or a fault in the charge controller. | This error can be due to other charging equipment connected to the battery or a fault in the charge controller. | ||
+ | This error can also occur if the battery voltage is set to a lower voltage than the actual battery voltage. | ||
==== Err 3, Err 4 - Remote temperature sensor failure ==== | ==== Err 3, Err 4 - Remote temperature sensor failure ==== | ||
Check if the T-sense connector is properly connected to a remote temperature sensor. | Check if the T-sense connector is properly connected to a remote temperature sensor. | ||
Line 30: | Line 33: | ||
==== Err 18 - Controller over-current ==== | ==== Err 18 - Controller over-current ==== | ||
This error will auto-reset. | This error will auto-reset. | ||
- | Disconnect | + | If the error does not auto-reset disconnect |
- | If the error persists the charge controller is probably faulty. | + | A cause for this error can be switching on a very large load on the battery side. |
==== Err 20 - Maximum Bulk-time exceeded ==== | ==== Err 20 - Maximum Bulk-time exceeded ==== | ||
Line 45: | Line 48: | ||
==== Err 21 - Current sensor issue ==== | ==== Err 21 - Current sensor issue ==== | ||
- | The charge controller is probably faulty. | + | |
This error will not auto-reset. | This error will not auto-reset. | ||
+ | Disconnect all wires, and then reconnect all wires. Also, make sure the minus on the MPPT charge controller (PV minus/ | ||
+ | |||
+ | If the error remains, please contact the dealer, there might be a hardware defect. | ||
==== Err 26 - Terminal overheated ==== | ==== Err 26 - Terminal overheated ==== | ||
Power terminals overheated, check wiring, including the wiring type and type of strands, and/or fasten bolts if possible. | Power terminals overheated, check wiring, including the wiring type and type of strands, and/or fasten bolts if possible. | ||
This error will auto-reset. | This error will auto-reset. | ||
+ | |||
+ | ==== Err 28 - Power stage issue ==== | ||
+ | |||
+ | This error will not auto-reset. | ||
+ | |||
+ | Disconnect all wires, and then reconnect all wires. If the error persists the charge controller is probably faulty. | ||
==== Err 33 - PV over-voltage ==== | ==== Err 33 - PV over-voltage ==== | ||
Line 59: | Line 71: | ||
==== Err 34 - PV over-current ==== | ==== Err 34 - PV over-current ==== | ||
The current from the solar-panel array has exceeded 75A. This error could be generated due to an internal system fault. | The current from the solar-panel array has exceeded 75A. This error could be generated due to an internal system fault. | ||
- | Disconnect the charger from all power-sources, | + | Disconnect the charger from all power-sources, |
- | This error will auto-reset. | + | |
- | ==== Err 38 - Input shutdown | + | ==== Err 38, Err 39 - PV Input shutdown ==== |
- | To protect the battery from over-charging the panel input is shut down. To recover from this condition first disconnect the solar panels and disconnect the battery. Wait for 3 minutes reconnect the battery first and next the panels. If the error persists the charge controller is probably faulty. | + | To protect the battery from over-charging the panel input is shorted. |
+ | |||
+ | Possible reasons for this error to occur: | ||
+ | * The Battery voltage (12/24/48V) is set, or auto-detected, | ||
+ | * There is another device connected to the battery, which is configured to a higher voltage. For example a MultiPlus, configured to equalise at 17 Volts, while in the MPPT this is not configured. | ||
+ | * The battery is disconnected using a manual switch. Ideally the charger should be switched off before disconnecting the battery, this avoids a voltage overshoot on the charger output. If necessary the voltage trip-level for the PV Short protection can be increased by raising the Equalization voltage set-point (note: equalization does not have to be enabled in this case). | ||
+ | * The battery is disconnected using a Lithium charge relay connected to the “allow-to-charge” output of a BMS. Consider wiring this signal to the Remote terminal of the charger instead. This shuts down the charger gracefully without creating a voltage overshoot. | ||
+ | |||
+ | Error recovery: | ||
+ | * Error 38: First disconnect the solar panels and disconnect the battery. Wait for 3 minutes, then reconnect the battery first and next the panels. | ||
+ | * Error 39: The charger will automatically resume operation once the battery voltage drops below the float level for 1 minute. | ||
+ | |||
+ | If the error persists the charge controller is probably faulty. | ||
==== Information 65 - Communication warning ==== | ==== Information 65 - Communication warning ==== | ||
Line 74: | Line 97: | ||
- | ==== Err 67 - No BMS ==== | + | ==== Err 67 - BMS Connection lost ==== |
- | The charger is configured to be controlled by a BMS, but it does not receive any control messages from a BMS. The charger stopped | + | The charger is configured to be controlled by a BMS, but it does not receive any control messages from a BMS. The charger stopped |
Check the connection between the charger and the BMS. | Check the connection between the charger and the BMS. | ||
Line 86: | Line 109: | ||
* VE.Direct solar chargers, reset the charger to factory defaults with VictronConnect, | * VE.Direct solar chargers, reset the charger to factory defaults with VictronConnect, | ||
- | Note that (solar-)chargers automatically configure themselves to be BMS-controlled when they are connected to one. | + | Note that (solar-)chargers automatically configure themselves to be BMS-controlled when they are connected to one; either direct or via a Color Control GX or Venus GX. |
- | ==== Err 114 - CPU temperature | + | ==== Err 68 - Network misconfigured ==== |
+ | |||
+ | The charger detects multiple conflicting network sources trying to take control of the charger. | ||
+ | |||
+ | Applies to SmartSolar MPPTs and SmartSolar MPPTs VE.Can. | ||
+ | |||
+ | The typical reason for the error to show is that the charger is configured to operate in parallel using our [[https:// | ||
+ | |||
+ | Resolution: disable the parallel operation by connecting VictronConnect, | ||
+ | |||
+ | For SmartSolar MPPT VE.Can only, also make sure its not connected to a [[https:// | ||
+ | |||
+ | Once the conflict is resolved the error will disappear and the charger will resume normal operation, usually within a minute. | ||
+ | |||
+ | |||
+ | |||
+ | ==== Err 114 - CPU temperature | ||
This error will reset after the CPU has cooled down. | This error will reset after the CPU has cooled down. | ||
If the error persists, check the ambient temperature and check for obstructions near the air inlet and outlet holes of the charger cabinet. | If the error persists, check the ambient temperature and check for obstructions near the air inlet and outlet holes of the charger cabinet. | ||
Line 94: | Line 133: | ||
==== Err 116 - Calibration data lost ==== | ==== Err 116 - Calibration data lost ==== | ||
- | The unit is faulty, contact | + | If the unit does not work and error 116 pops up as the active error the unit is faulty, contact |
+ | If the error is only present in the history data and the unit operates normally this error can be ignored safely. Explanation: | ||
+ | |||
+ | SmartSolar models (not the BlueSolar models): upgrading to v1.4x firmware is a one-way trip, you cannot go back to an older firmware version once you upgrade to v1.4x. Reverting to older firmware gives error 116 (calibration data lost), this can be fixed by re-installing the v1.4x firmware. | ||
==== Err 119 - Settings data lost ==== | ==== Err 119 - Settings data lost ==== | ||
The charger cannot read its configuration, | The charger cannot read its configuration, | ||
Line 104: | Line 146: | ||
- wait 3 minutes, and power up again. | - wait 3 minutes, and power up again. | ||
- Reconfigure the charger. | - Reconfigure the charger. | ||
+ | |||