| + | ==== Err 77 - Settings sync disabled ==== | ||
| + | Applies to Inverter RS and Multi RS models. Firmware v1.29 and higher. | ||
| + | |||
| + | This is a warning that indicates a mixed configuration in a networked setup where system settings synchronisation is enabled on some devices but not on all units. The units that have the settings synchronisation disabled show this warning. The units remain operational, | ||