| Line 13: | Line 13: | ||
| * Modules per stack: **7 or 8** (the Pylontech product documentation allows 2 - 7; 6 or fewer sits below the HS19 voltage range, Pylontech permits either 7 or 8 to be used with Victron HS19) | * Modules per stack: **7 or 8** (the Pylontech product documentation allows 2 - 7; 6 or fewer sits below the HS19 voltage range, Pylontech permits either 7 or 8 to be used with Victron HS19) | ||
| * Usable voltage range: **650 - 920 V**. A 7 module stack discharge floor is 649 V (estimated at 2.9 V/cell). | * Usable voltage range: **650 - 920 V**. A 7 module stack discharge floor is 649 V (estimated at 2.9 V/cell). | ||
| - | * Capacity: | + | * Capacity: 36 kWh per 7 module |