Line 894: Line 894:
 Switching off in overload, while connected to the grid, is caused by the active Loss of Mains (LOM) detection, linked to the country code as configured in VEConfigure3. Switching off in overload, while connected to the grid, is caused by the active Loss of Mains (LOM) detection, linked to the country code as configured in VEConfigure3.
  
-This behaviour occurs when the AC supplied on the AC-in of the Multi or Quattro is 'weak'. By 'weak' we mean that the AC connection to the utility has a higher impedance than usual. For example a generator, or an old or remote house connected with a too-long and/or too/thin cable to the utility.+This behaviour occurs when the AC supplied on the AC-in of the Multi or Quattro is 'weak'. By 'weak' we mean that the AC connection to the utility has a higher impedance than usual. For example a generator, or house connected with a too-long and/or too-thin cable from the Inverter/Charger to the utility.
  
 For the solution and configuration options, see [[ve.bus:grid-codes-and-loss-of-mains-detection|]]. For the solution and configuration options, see [[ve.bus:grid-codes-and-loss-of-mains-detection|]].