Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
energy-meters:et112 [2019-01-22 10:16] – external edit 127.0.0.1 | energy-meters:et112 [2020-06-27 13:23] – [Option A: wireless Zigbee connection] - note on compatibility boekel | ||
---|---|---|---|
Line 30: | Line 30: | ||
**Grid Meter** - Wiring when used as a grid meter. | **Grid Meter** - Wiring when used as a grid meter. | ||
- | This configuration option of either Grid Meter, or PV Inverter is set in the [[venus-os: | + | This configuration option of either Grid Meter, or PV Inverter is set in the [[venus-os: |
==== Example Diagram ==== | ==== Example Diagram ==== | ||
Line 56: | Line 56: | ||
Connect the Zigbee to RS485 converter to the ET112 energy meter: | Connect the Zigbee to RS485 converter to the ET112 energy meter: | ||
- | ^ Zigbee Converter ^ Energy meter ^ | + | ^ Zigbee Converter ^ Energy meter ^ Color ^ |
- | | GND | Terminal 6 | | + | | GND | Terminal 6 | Black | |
- | | A | Terminal 4 | | + | | A | Terminal 4 | Orange |
- | | B | Terminal 5 | | + | | B | Terminal 5 | Yellow |
| | ||
=== Step 3. === | === Step 3. === | ||
Line 67: | Line 67: | ||
Connect the 12V DC power supply to the Zigbee to RS485 converter. When the power is switched on, check the LEDs again. | Connect the 12V DC power supply to the Zigbee to RS485 converter. When the power is switched on, check the LEDs again. | ||
+ | === note on old and new zigbee converters === | ||
+ | Please note that there is a new zigbee converter available now, that is -not- backwards compatible with the old converters. If you have a non compatible set, please ask your supplier for a correct version. | ||
+ | |||
+ | ' | ||
+ | |||
+ | ASS300400100 - Zigbee to RS485 converter partnumber: DRF2619C | ||
+ | |||
+ | ASS300400100 - Zigbee to USB converter | ||
+ | |||
+ | ' | ||
+ | |||
+ | ASS300420100 - Zigbee to RS485 converter partnumber: DRF2659C | ||
+ | |||
+ | ASS300420200 - Zigbee to USB converter | ||
==== Option B: Wired connection to CCGX ==== | ==== Option B: Wired connection to CCGX ==== | ||
Line 97: | Line 111: | ||
Connecting multiple ET112 meters to the same RS485-USB cable is not possible: the ET112 meter has no display and its Modbus address can therefor not be changed. | Connecting multiple ET112 meters to the same RS485-USB cable is not possible: the ET112 meter has no display and its Modbus address can therefor not be changed. | ||
- | Note 1 You can connect the ET112 in parallel, just need to change the MOD address to another number using the Configuration | + | Note 1 You can connect the ET112 in parallel, just need to change the MOD address to another number using the Configuration software from the supplier which is free from Carlo Gavazzi Web site. |
- | software from the supplier which is free from Carlo Gavazzi Web site. | + | |
===== DISQUS ===== | ===== DISQUS ===== | ||
~~DISQUS~~ | ~~DISQUS~~ | ||
energy-meters/et112.txt · Last modified: 2022-07-15 10:58 by stefanie