Line 1: | Line 1: | ||
- | ====== ACin ignore timer using CCGX Generator auto start/ | + | ====== |
Note that below functionality requires Color Control GX version v1.30 or newer. See [[ccgx: | Note that below functionality requires Color Control GX version v1.30 or newer. See [[ccgx: | ||
Line 14: | Line 14: | ||
==== Set the Test run condition ==== | ==== Set the Test run condition ==== | ||
- | Allows | + | The ' |
We will use the test run condition to set the time when the relay will be closed. No other conditions will be used in this example. | We will use the test run condition to set the time when the relay will be closed. No other conditions will be used in this example. | ||
{{: | {{: | ||
- | * **Test run interval**: Interval for the test run. For this examaple | + | * **Test run interval**: Interval for the test run. For this example |
* **Skip test run if has been running for**: For this example will be set to: Start always | * **Skip test run if has been running for**: For this example will be set to: Start always | ||
* **Test interval start date**: The interval count will start based on this date, this setting can be set in the future and the interval will be ignored till the set date is reached. | * **Test interval start date**: The interval count will start based on this date, this setting can be set in the future and the interval will be ignored till the set date is reached. | ||
Line 26: | Line 26: | ||
===== Assistant Settings ===== | ===== Assistant Settings ===== | ||
- | To make it work add and configure the assistants: General flag user and Programmable relay | + | To make it work add and configure the assistants: |
- | | + | Move the General Flag user assistant to the end of the list |
+ | |||
+ | | ||
Set to: Use general flag to ignore AC input 1 | Set to: Use general flag to ignore AC input 1 | ||
| | ||
- | | + | |
- | You need to of the ' | + | You need to 2 instances |
- | ** Set Flag when relais | + | ** Set Flag when relay is open ** |
+ | * Relay: Use General Flag | ||
* Action: Set relay on | * Action: Set relay on | ||
+ | * Switch conditions : Set checkbox: Input signal (Auxilary 1, Auxilary 2 or Temp sense input) | ||
+ | * Extra drive options: leave open | ||
+ | * Drive based on input signal: Choose correct input. set to open and 5 second | ||
** Clear Flag when relais is closed ** | ** Clear Flag when relais is closed ** | ||
+ | * Relay: Use General Flag | ||
+ | * Action: Set relay off | ||
+ | * Switch conditions : Set checkbox: Input signal (Auxilary 1, Auxilary 2 or Temp sense input) | ||
+ | * Extra drive options: leave open | ||
+ | * Drive based on input signal: Choose correct input. set to close and 5 second | ||
==== Wire the ColorControl relay to the Aux of Temp input on the Multi ==== | ==== Wire the ColorControl relay to the Aux of Temp input on the Multi ==== | ||
- | Last step is to wire the ColorControl relay to an AUX of Temp input that is defined in the assistant setup. The relay will short the input. The assistant will not ignore ACin when the relais is closed. | + | Last step is to wire the ColorControl relay to an AUX or Temp input that is defined in the assistant setup. The relay will short the input and the assistant will not ignore ACin when the relais is closed. |
| | ||
| | ||
+ | |||
===== DISQUS ===== | ===== DISQUS ===== | ||