ccgx:fischer_panda
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
ccgx:fischer_panda [2019-07-11 08:50] – [Menu] mvader | ccgx:fischer_panda [2020-09-07 12:29] (current) – [Maintenance] mvader | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== | + | ====== |
+ | |||
+ | Fischer Panda generator can be connected to a GX Device, which makes it possible to monitor & operate the generator as well as automatically start and stop it. | ||
+ | |||
+ | The generator needs to be connected to the VE.Can port of the GX Device, which requires a Fischer Panda SAE J1939 module. | ||
- | Beginning with the release of [[https:// | ||
===== Requirements ===== | ===== Requirements ===== | ||
- | * CCGX or Venus GX | + | * [[venus-os: |
* Fischer Panda generator, xControl or iGenerator | * Fischer Panda generator, xControl or iGenerator | ||
* Fischer Panda SAE J1939 CAN module (part number 0006107) | * Fischer Panda SAE J1939 CAN module (part number 0006107) | ||
Line 45: | Line 48: | ||
{{: | {{: | ||
===== Generator start/stop ===== | ===== Generator start/stop ===== | ||
- | In addition to the manual start/stop and monitoring, there is also an automatic start/stop feature. This has the same comprehensive range of options as the Generator start/stop feature associated with the CCGX relay. | + | In addition to the manual start/stop and monitoring, there is also an automatic start/stop feature. This has the same comprehensive range of options as the Generator start/stop feature associated with the GX relay. |
See [[ccgx: | See [[ccgx: | ||
Line 55: | Line 58: | ||
When the maintenance is completed, make sure you enable the autostart feature again. You can do this on the Fischer Panda control panel in the menu '' | When the maintenance is completed, make sure you enable the autostart feature again. You can do this on the Fischer Panda control panel in the menu '' | ||
+ | ===== MFD App ==== | ||
+ | |||
+ | The Marine MFD HTML5 app (more information [[https:// | ||
+ | |||
+ | {{ : | ||
===== Troubleshooting ===== | ===== Troubleshooting ===== | ||
=== I've set the mode of the genset to ' | === I've set the mode of the genset to ' | ||
- | Make sure the Fischer Panda autostart feature is on, this allows the CCGX control the remote on/off of the genset. You can find this option on the control panel in the menu '' | + | Make sure the Fischer Panda autostart feature is on, this allows the GX control the remote on/off of the genset. You can find this option on the control panel in the menu '' |
If you're manually trying to start the genset, a toast message appears with the text '' | If you're manually trying to start the genset, a toast message appears with the text '' | ||
Line 67: | Line 75: | ||
- | ===== DISQUS ===== | + | |
- | ~~DISQUS~~ | + | |
ccgx/fischer_panda.1562827844.txt.gz · Last modified: 2019-07-11 08:50 by mvader