ccgx:abb_fimer
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
ccgx:abb [2019-05-20 10:48] – created iburger | ccgx:abb_fimer [2021-06-16 15:30] (current) – [1. Introduction] rgerber | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== CCGX & ABB PV Inverters ====== | + | ====== CCGX & ABB/ |
===== 1. Introduction ===== | ===== 1. Introduction ===== | ||
- | By connecting an ABB PV Inverter and [[https:// | + | By connecting an ABB/ |
- | - See ABB information on the CCGX. | + | - See ABB/ |
- | - Monitor the ABB inverter on the VRM Portal. | + | - Monitor the ABB/ |
- Allow the Victron system to control the output power, Zero feed-in. This uses the same mechanism used for Fronius PV inverters. See the [[ess: | - Allow the Victron system to control the output power, Zero feed-in. This uses the same mechanism used for Fronius PV inverters. See the [[ess: | ||
- | - Frequency shift power control, as explained in a [[ac_coupling: | + | - Frequency shift power control, as explained in [[ac_coupling: |
+ | {{: | ||
===== 2. Supported models ===== | ===== 2. Supported models ===== | ||
Models that are known to work are: | Models that are known to work are: | ||
- | ^ Model | + | ^ Model |
- | | UNO-DM-PLUS | + | | UNO-DM-PLUS/PLUS-Q | Works |
- | | TRIO-TM-50/ | + | | TRIO-TM-50/ |
- | | PVS-100/ | + | | PVS-100/ |
- | | PVS-50/60 | Untested, but expected to work. | | + | | PVS-10/ |
===== 3. Configuration ===== | ===== 3. Configuration ===== | ||
- | Please consult the manual that came with your ABB PV inverter. This explains how to connect your ABB inverter to the network using either an Ethernet or a WiFi connection. Commissioning the inverter | + | Please consult the manual that came with your ABB/ |
+ | You can also use the " | ||
+ | |||
+ | Commissioning the inverter | ||
+ | |||
+ | When using the app, simply scan the QR code for the WiFi access and follow instructions on the app. This can be used to program multiple inverters simultaneously. | ||
+ | |||
+ | When using the webserver, follow instructions below: | ||
- | - Switch on DC power to inverter (leave AC off) | + | - Switch on DC power to inverter (leave AC off). |
- | - Using a web browser, connect to the inverter' | + | - Using a web browser, connect to the inverter' |
- | - Follow the steps in the wizard | + | - Follow the steps in the wizard. |
- | - Obtain the admin plus password from your distributor | + | - Obtain the admin plus password from your distributor. |
- | - Enter the inverter AC settings | + | - Enter the inverter AC settings. |
- | - Set up the frequency shift and ramp control accordingly | + | - Set up the frequency shift and ramp control accordingly. |
+ | - Switch on AC and test operation of system. | ||
===== 4. Adding the ABB inverter to the CCGX ===== | ===== 4. Adding the ABB inverter to the CCGX ===== | ||
- In the CCGX, navigate to // | - In the CCGX, navigate to // | ||
- | - Select //Scan// in the CCGX menu, and after completion go into the Inverters submenu to see the results. If scanning does not find the inverter, manually add the IP address of the ABB inverter. | + | - Select //Scan// in the CCGX menu, and after completion go into the Inverters submenu to see the results. If scanning does not find the inverter, manually add the IP address of the ABB/ |
- Once located, you will see the Inverters listed in the menu. The name used will be the serial number of the inverter. | - Once located, you will see the Inverters listed in the menu. The name used will be the serial number of the inverter. | ||
- Configure the // | - Configure the // |
ccgx/abb_fimer.1558342092.txt.gz · Last modified: 2019-05-20 10:48 by iburger