Both sides previous revisionPrevious revision | |||
battery_compatibility:solar_md [2022-06-18 08:50] – [7.1 Communication Cable Connection] kaloyan | battery_compatibility:solar_md [2022-06-18 14:14] (current) – kaloyan | ||
---|---|---|---|
Line 299: | Line 299: | ||
The minimum firmware version of the BMS EX should be v 178 | The minimum firmware version of the BMS EX should be v 178 | ||
+ | {{: | ||
+ | ==== 7.2 A Battery settings ==== | ||
+ | Refer to the BMS of LoggerV manual to configure the CANBUS 2 interface for a Victron device. Note: After changing CANBUS 2 settings on the battery, the Victron GX device will need to be rebooted. | ||
- | ==== 1.2 A GX device is required, eg Color Control GX (CCGX), Venus GX (VGX), etc ==== | ||
- | It is essential to use the CAN-bus connection of a [[venus-os: | ||
- | When used with Solar MD batteries, the minimum required firmware version for the [[venus-os: | ||
- | ==== 1.3 All 48V Multis, MultiPlusses, | ||
- | |||
- | The minimum firmware version is 422. Though updating to the latest firmware is recommended where possible. | ||
- | These inverter/ | ||
- | In grid-connected systems, advanced control functions are configurable in the ESS settings on the [[venus-os: | ||
- | In off-grid systems, the control functions of the SOLARMD Battery Management System (BMS) are built into the latest version of the [[venus-os: | ||
- | |||
- | ==== 1.4 All 48V BlueSolar and SmartSolar MPPT Chargers are compatible ==== | ||
- | |||
- | For proper operation, the Battery battery needs to be able to control the charge current of the solar MPPTs. It is recommended to use the MPPTs with VE. Direct port with SOLARMD batteries. | ||
- | MPPTs with a VE.Direct port | ||
battery_compatibility/solar_md.1655535043.txt.gz · Last modified: by kaloyan