User Tools

Site Tools


battery_compatibility:solar_md

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revisionBoth sides next revision
battery_compatibility:solar_md [2019-08-15 11:46] – replace Venus-device with GX device guy_stewartbattery_compatibility:solar_md [2019-09-23 06:22] – solar_md_portal.png change kaloyan
Line 103: Line 103:
 Each battery module is 72Ah (SS4037) or 144Ah (SS4074) at 48V (51.2V nominal). Each battery module is 72Ah (SS4037) or 144Ah (SS4074) at 48V (51.2V nominal).
  
-The following charge rates are managed automatically by the SolarMD LOGGER V2 and [[venus-os:start|GX device]]. Temperature effects on charge rates should be considered in the design stage in extreem hot and cold climates.+The following charge rates are managed automatically by the SolarMD LOGGER V2 and [[venus-os:start|GX device]]. Temperature effects on charge rates should be considered in the design stage in extreme hot and cold climates.
  
 Using very large solar arrays with battery banks that are too small can exceed the limits of the batteries ability to charge and possibly lead to the LOGGER V2 triggering over-current alarms. Using very large solar arrays with battery banks that are too small can exceed the limits of the batteries ability to charge and possibly lead to the LOGGER V2 triggering over-current alarms.
Line 233: Line 233:
 ---- ----
  
-  * On the Solar MD portal ([[http://login.mypower24.co.za]]) Select Victron CAN Translator on CAN2: +  * On the Solar MD portal ([[http://login.mypower24.co.za]]) Select Victron Bridge on CAN2: 
 Menu path:  Menu path: 
  
-My Devices → Logger → Interfaces → CANBUS2 . After choosing Victron CAN Translator, proceed with Software reboot on the Logger V2 in the Tab  "System Settings"+My Devices → Logger → Interfaces → CANBUS2. After choosing Victron Bridge, proceed with Software reboot on the Logger V2 in the Tab  "System Settings"
  
 {{:battery_compatibility:solar_md_portal.png?direct |}} {{:battery_compatibility:solar_md_portal.png?direct |}}
 +
  
 ---- ----
Line 277: Line 278:
 |Battery voltage.     |48V| |Battery voltage.     |48V|
 |Absorption voltage   |54.6V| |Absorption voltage   |54.6V|
- 
  
battery_compatibility/solar_md.txt · Last modified: 2022-06-18 14:14 by kaloyan