User Tools

Site Tools


battery_compatibility:solar_md

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
battery_compatibility:solar_md [2019-07-27 12:52] – [5. Venus-device and LoggerV2 Configuration] kaloyanbattery_compatibility:solar_md [2019-07-27 16:36] – [Victron & SOLARMD Battery] kaloyan
Line 3: Line 3:
 The combination of Victron products with SolarMD Battery lithium batteries has been tested and certified by the Solar MD R&D department. This combination has extensive field experience and is actively supported by Solar MD. The combination of Victron products with SolarMD Battery lithium batteries has been tested and certified by the Solar MD R&D department. This combination has extensive field experience and is actively supported by Solar MD.
  
-The SolarMD Battery includes an integrated Battery Management System (BMS) with each battery module and a Battery Management Unit (LOGGER V2that interfaces with the Victron [[venus-os:start|Venus-device]] and supports multiple battery modules.+The SolarMD Battery includes an integrated Battery Management System (BMS) with each battery module and a LOGGER V2 that interfaces with the Victron [[venus-os:start|Venus-device]] and supports multiple battery modules. 
 + 
 + 
 +== Supported models == 
 + 
 +^ Model ^ SS4037^ SS4074^ SS202^  
 +| Battery | {{ :battery_compatibility:solar_md_3.7kwh.jpg?direct&200% |}} | {{ :battery_compatibility:img_6542.jpg?direct&200% |}} | {{ :battery_compatibility:img_9807sqlogobox.jpg?direct&200% |}} |  
 +|ESS | yes| yes| yes| 
 +|Grid Backup | yes| yes| yes| 
 +|Off-Grid | yes| yes| yes| 
 +|Module capacity | 3.7kWh| 7,4kWh| 7,4kWh| 
 +|Module limit | 256| 256| 256| 
 +|Max capacity | 947 kWh| 1894,4 kWh| 1894,4 kWh| 
 +|Logger V2 | yes| yes| yes| 
 + 
 +== Typical System overview == 
 + 
 +{{:battery_compatibility:solarmd-victron_wiring.jpg?direct |}} 
 + 
 + 
  
-^ Battery ^ SS4037 ^ SS4074 ^ SS202 ^ SS237-25.6V ^  
-| ESS | yes | yes | yes | yes | 
-| Grid Backup | yes | yes | yes | yes | 
-| Off-Grid | yes | yes | yes | yes | 
-| Module capacity | 3.7 kWh | 7.4 kWh |7.4 kWh | 3.7kWh | 
-| Module limit | 256 | 256 | 256 | 256 | 
-| Max capacity | 947 kWh | 1894,4 kWh | 1894,4 kWh | 947 kWh | 
  
 For SS237 - 25.6V (24V systems) please contact [[support@solarmd.co.za|Solar MD support team]] for further assistance. For SS237 - 25.6V (24V systems) please contact [[support@solarmd.co.za|Solar MD support team]] for further assistance.
Line 108: Line 121:
 ===== 3. CAN Bus Wiring ===== ===== 3. CAN Bus Wiring =====
  
-Use any UTP cable. Plug 3 of the wires into the SOLARMD BMS. Plug the other side with RJ45 connector into the [[venus-os:start|Venus-device]].+Use any UTP cable. Plug 3 of the wires (PIN 7, PIN 8, PIN 3) into the SolarMD LoggerV2. Plug the other side with RJ45 connector into the [[venus-os:start|Venus-device]].
  
 {{ :battery_compatibility:canbus_solarmd.png |}} {{ :battery_compatibility:canbus_solarmd.png |}}
battery_compatibility/solar_md.txt · Last modified: 2022-06-18 14:14 by kaloyan