User Tools

Site Tools


battery_compatibility:pylontech_phantom

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
battery_compatibility:pylontech_phantom [2019-02-28 11:46] guy_stewartbattery_compatibility:pylontech_phantom [2019-05-17 15:01] – [1. Product & system compatibility] mvader
Line 1: Line 1:
-====== Victron & Pylontech US2000B and Phantom-S =====+====== Victron & Pylontech US2000, US3000 and Phantom-S =====
  
 The combination of Victron products with Pylontech lithium batteries has been tested and certified by the Victron and Pylontech R&D departments.  The combination of Victron products with Pylontech lithium batteries has been tested and certified by the Victron and Pylontech R&D departments. 
Line 13: Line 13:
 {{:battery_compatibility:pylontech_battery.png?direct&600|}} {{:battery_compatibility:pylontech_battery.png?direct&600|}}
  
-^  Battery ^  US2000B ^  US2000B Plus ^  US3000 Plus +^  Battery ^  US2000 (Plus^ US3000 ^ Force-L1 
-|  Module capacity|  2.4 kWh |  2.kWh |  3.kWh| +|  Module capacity|  2.4 kWh |  3.kWh| 3.55 kWh |
  
 === 1.1 Offgrid, Backup and Energy Storage Systems are possible === === 1.1 Offgrid, Backup and Energy Storage Systems are possible ===
Line 25: Line 25:
  
  
-=== 1.2 A Venus-device is required, eg Color Control GX (CCGX) or Venus GX (VGX) === +=== 1.2 A GX-device is required, eg Color Control GX (CCGX) or Venus GX (VGX) === 
  
 It is essential to use the CAN-bus connection of the [[venus-os:start|Venus-device]] (eg CCGX or VGX) with the batteries for the keep-alive signal, communication of charge and discharge limits, error codes and state of charge.  It is essential to use the CAN-bus connection of the [[venus-os:start|Venus-device]] (eg CCGX or VGX) with the batteries for the keep-alive signal, communication of charge and discharge limits, error codes and state of charge. 
Line 88: Line 88:
 The batteries will automatically detect and link to each other, no adjustment of dip switches or software changes are necessary on the batteries.  The batteries will automatically detect and link to each other, no adjustment of dip switches or software changes are necessary on the batteries. 
  
-The battery with the empty link port 0 is the master battery. Using the //VE.Can to CAN-bus BMS type B Cable//, part number ASS030720018, Plug the side which is labeled Battery BMS into the Pylontech CAN port of the master battery. Plug the side labeled Victron VE.Can into the [[venus-os:start|Venus-device]].+The battery with the empty link port 0 is the master battery.  
 +You must use the //VE.Can to CAN-bus BMS type B Cable//, part number ASS030720018, you cannot use the cable supplied by Pylontech.  
 + 
 +Plug the type B cable with the side which is labeled Battery BMS into the Pylontech CAN port of the master battery. Plug the side labeled Victron VE.Can into the [[venus-os:start|GX device]].
  
 Then, plug a [[https://www.victronenergy.com/accessories/ve-can-rj45-terminator|VE.Can terminator]] in the other VE.Can socket on the [[venus-os:start|Venus-device]]. Two VE.Can terminators are included with the package of the [[venus-os:start|Venus-device]] as an accessory, only one is used. Keep the other one as a spare. Then, plug a [[https://www.victronenergy.com/accessories/ve-can-rj45-terminator|VE.Can terminator]] in the other VE.Can socket on the [[venus-os:start|Venus-device]]. Two VE.Can terminators are included with the package of the [[venus-os:start|Venus-device]] as an accessory, only one is used. Keep the other one as a spare.
battery_compatibility/pylontech_phantom.txt · Last modified: 2023-11-13 14:41 by guy_stewart