User Tools

Site Tools


battery_compatibility:pylontech_phantom

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
battery_compatibility:pylontech_phantom [2019-01-22 10:16] – external edit 127.0.0.1battery_compatibility:pylontech_phantom [2019-05-06 11:28] – [3. CAN-bus Wiring] guystewart
Line 31: Line 31:
 The minimum required firmware version for the [[https://www.victronenergy.com/panel-systems-remote-monitoring/color-control|Color Control GX]] is v2.15. It is highly recommended to use the latest firmware version on all connected devices, including CCGX/VGX, Inverter/Charger and MPPTs. There are regular updates to improve performance and reliability.  The minimum required firmware version for the [[https://www.victronenergy.com/panel-systems-remote-monitoring/color-control|Color Control GX]] is v2.15. It is highly recommended to use the latest firmware version on all connected devices, including CCGX/VGX, Inverter/Charger and MPPTs. There are regular updates to improve performance and reliability. 
  
-In grid connected systems, advanced control functions are configurable in the ESS settings on the [[venus-os:start|Venus-device]]. 
- 
-In off-grid systems, the system control functions from the Pylontech Battery Management System (BMS) are built into the latest version of the [[venus-os:start|Venus-device]]. 
  
 === 1.3 All 48V Multi, MultiPlus, MultiGrid and Quattro are compatible === === 1.3 All 48V Multi, MultiPlus, MultiGrid and Quattro are compatible ===
Line 91: Line 88:
 The batteries will automatically detect and link to each other, no adjustment of dip switches or software changes are necessary on the batteries.  The batteries will automatically detect and link to each other, no adjustment of dip switches or software changes are necessary on the batteries. 
  
-The battery with the empty link port 0 is the master battery. Using the //VE.Can to CAN-bus BMS type B Cable//, part number ASS030720018, Plug the side which is labeled Battery BMS into the Pylontech CAN port of the master battery. Plug the side labeled Victron VE.Can into the [[venus-os:start|Venus-device]].+The battery with the empty link port 0 is the master battery.  
 +You must use the //VE.Can to CAN-bus BMS type B Cable//, part number ASS030720018, you cannot use the cable supplied by Pylontech.  
 + 
 +Plug the type B cable with the side which is labeled Battery BMS into the Pylontech CAN port of the master battery. Plug the side labeled Victron VE.Can into the [[venus-os:start|GX device]].
  
 Then, plug a [[https://www.victronenergy.com/accessories/ve-can-rj45-terminator|VE.Can terminator]] in the other VE.Can socket on the [[venus-os:start|Venus-device]]. Two VE.Can terminators are included with the package of the [[venus-os:start|Venus-device]] as an accessory, only one is used. Keep the other one as a spare. Then, plug a [[https://www.victronenergy.com/accessories/ve-can-rj45-terminator|VE.Can terminator]] in the other VE.Can socket on the [[venus-os:start|Venus-device]]. Two VE.Can terminators are included with the package of the [[venus-os:start|Venus-device]] as an accessory, only one is used. Keep the other one as a spare.
Line 230: Line 230:
  
 The Pylontech manual contains additional diagnostic and troubleshooting information, specifically around decoding any indicator LEDs. The Pylontech manual contains additional diagnostic and troubleshooting information, specifically around decoding any indicator LEDs.
-===== 9. FAQ ===== 
  
-**The maximum charge and discharge current is limited to 25A, but the data sheet tells me the maximum is 100A.** +===== 9. FAQ and Known Issues===== 
 + 
 +==== The maximum charge and discharge current is limited to 25A, but the data sheet tells me the maximum is 100A. ====
  
 The maximum current is limited to keep the battery healthy and reach the 10 year guarantee. In off-grid, the inverter can draw more than the 25A limit to run the loads, make sure you have sufficient batteries installed to keep the load per battery around this limit. The maximum current is limited to keep the battery healthy and reach the 10 year guarantee. In off-grid, the inverter can draw more than the 25A limit to run the loads, make sure you have sufficient batteries installed to keep the load per battery around this limit.
  
-**After charging the battery the charge current often changes between 0A and 25A.** +==== After charging the battery the charge current often changes between 0A and 25A. ==== 
 This is caused by cell balancing inside the battery. This happens with new batteries and after a deep discharge. This is caused by cell balancing inside the battery. This happens with new batteries and after a deep discharge.
  
 +==== My system isn't charging at the rated capacity, or my PV is shutting down ====
  
 +Pylontech's BMS will restrict the Charge Current Limit of the battery in cold weather. The precise temperatures and limits are not published by Pylontech, but anecdotally from reports on [[http://commmunity.victronenergy.com|Victron Community]] it would appear that batteries begin to be limited below 18 degree C, severely limited below 10 degrees C, and completely restricted from charging below 2 degrees C. 
 +
 +You can confirm if this is affecting your installation be entering the Pylontech Battery menu on your Venus-device, and then the Parameters Menu. This will report the Charge Current Limit (CCL) and Discharge Current Limit (DCL).
  
 ===== 10. Further Information ===== ===== 10. Further Information =====
Line 251: Line 257:
 ===== DISQUS ===== ===== DISQUS =====
 ~~DISQUS~~ ~~DISQUS~~
- 
battery_compatibility/pylontech_phantom.txt · Last modified: 2023-11-13 14:41 by guy_stewart

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki