The minimum required firmware version for the [[https:// | The minimum required firmware version for the [[https:// | ||
- | In grid connected systems, advanced control functions are configurable in the ESS settings on the [[venus-os: | ||
- | |||
- | In off-grid systems, the system control functions from the Pylontech Battery Management System (BMS) are built into the latest version of the [[venus-os: | ||
=== 1.3 All 48V Multi, MultiPlus, MultiGrid and Quattro are compatible === | === 1.3 All 48V Multi, MultiPlus, MultiGrid and Quattro are compatible === | ||
Line 230: | Line 227: | ||
The Pylontech manual contains additional diagnostic and troubleshooting information, | The Pylontech manual contains additional diagnostic and troubleshooting information, | ||
- | ===== 9. FAQ ===== | ||
- | **The maximum charge and discharge current is limited to 25A, but the data sheet tells me the maximum is 100A.** | + | ===== 9. FAQ and Known Issues===== |
+ | |||
+ | ==== The maximum charge and discharge current is limited to 25A, but the data sheet tells me the maximum is 100A. ==== | ||
The maximum current is limited to keep the battery healthy and reach the 10 year guarantee. In off-grid, the inverter can draw more than the 25A limit to run the loads, make sure you have sufficient batteries installed to keep the load per battery around this limit. | The maximum current is limited to keep the battery healthy and reach the 10 year guarantee. In off-grid, the inverter can draw more than the 25A limit to run the loads, make sure you have sufficient batteries installed to keep the load per battery around this limit. | ||
- | **After charging the battery the charge current often changes between 0A and 25A.** | + | ==== After charging the battery the charge current often changes between 0A and 25A. ==== |
This is caused by cell balancing inside the battery. This happens with new batteries and after a deep discharge. | This is caused by cell balancing inside the battery. This happens with new batteries and after a deep discharge. | ||
+ | ==== My system isn't charging at the rated capacity, or my PV is shutting down ==== | ||
+ | |||
+ | Pylontech' | ||
+ | You can confirm if this is affecting your installation be entering the Pylontech Battery menu on your Venus-device, | ||
===== 10. Further Information ===== | ===== 10. Further Information ===== | ||